LXT / 330 / N Two-Wire Liquid Analyser, One Digital Sensor, 4 to 20 mA and MODBUS
The LXT / 330 / N belongs to the LXT series and has one channel for a single digital sensor, such as pH, ORP, pION, dissolved oxygen, conductivity, resistivity or suspended solids. It draws its power from the current loop in a two-wire scheme and provides 4 to 20 mA and MODBUS outputs.
- Model
- LXT330
- First channel
- 1 digital sensor: SP3, pH, ORP, pION, DO, ppb DO, conductivity, resistivity, TSS, ODO
- Second channel
- 0, none
- Power and relay
- 00 (LOOP), two-wire scheme, one channel only
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The LXT330 is intended for continuous measurement of water and process liquids with a single digital sensor. This version provides one measuring channel with no second channel, and mounting hardware is not included in the supply.
The first channel takes one digital sensor, either the SP3 type or a sensor for pH, redox potential (ORP), pION for ion-selective work, dissolved oxygen (DO), trace dissolved oxygen in ppb, optical dissolved oxygen (ODO), conductivity, resistivity or total suspended solids (TSS). The sensor is chosen for the task, whether that means checking acidity, oxidising processes, oxygen content in feed or waste water, salinity or turbidity.
Power code 00 (LOOP) denotes a two-wire scheme in which the instrument takes its supply from the 4 to 20 mA loop, so no separate supply cable is needed. Output code 0 gives a 4 to 20 mA analogue signal together with a MODBUS digital interface. The current signal feeds a controller or recorder input, while MODBUS passes data to a higher-level system. Mounting code 00 means the unit ships without fixings, which are selected to suit the site. This power arrangement is available only with a single channel.
The LXT380 is another model in the same series, carrying a different code. When ordering, state the full configuration code, covering the model, the first and second channels, power and relay, outputs and mounting.
Technical specifications
| Model | LXT330 |
|---|---|
| First channel | 1 digital sensor: SP3, pH, ORP, pION, DO, ppb DO, conductivity, resistivity, TSS, ODO |
| Second channel | 0, none |
| Power and relay | 00 (LOOP), two-wire scheme, one channel only |
| Outputs | 0, 4–20 mA and MODBUS |
| Mounting | 00, no mounting hardware |
Part numbers
Show all part numbers (2)
LXT330, LXT380
Request a price and lead time
LXT / 330 / N Two-Wire Liquid Analyser, One Digital Sensor, 4 to 20 mA and MODBUS. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the analyser need a separate power supply?
No. In the 00 (LOOP) version the unit is powered from the 4 to 20 mA current loop in a two-wire scheme.
Which sensors can be connected?
One digital sensor: SP3, pH, ORP, pION, dissolved oxygen DO, ppb DO or ODO, conductivity, resistivity or TSS.
How does the analyser send its data?
Through a 4 to 20 mA analogue output and a MODBUS digital interface.