International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

LXT 380 Explosion-Protected Liquid Transmitter, Ex db mb [ia IIC Ga] IIC T4 Gb

The LXT 380 works with one or two digital SP3X sensors and measures pH, ORP, specific ion (pION) parameters, dissolved oxygen, free and total chlorine, chlorine dioxide, conductivity and resistivity. The 316 stainless steel housing is available with FM, ATEX and IECEx certification for hazardous areas.

Sensors
digital SP3X, 1 or 2 channels
Measured parameters
pH, ORP, pION, dissolved oxygen, free and total chlorine, chlorine dioxide, conductivity, resistivity, turbidity
pH range
-1 to 15 pH
ORP range
-1500 to +1500 mV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The LXT 380 is used for continuous online measurement of liquids in hazardous industrial environments, where the housing and the sensor sit in a hazardous area. It measures pH, ORP, specific ion (pION) parameters, dissolved oxygen, free and total chlorine, chlorine dioxide, conductivity, resistivity and turbidity. Models FCA380 and CDA380 are built under the same certificate.

The transmitter exchanges data with a digital SP3X sensor and, using that sensor's data, sets up its menu and display for the parameter being measured. It takes one or two channels. The standard configuration has a 4-20 mA output and an RS485 serial port with Modbus RTU, and HART is optional on the single-channel version. It is powered either by a loop, which is single channel only, or by 24 VDC. Three SPDT relays are possible only with DC power. Power consumption is 4 W.

The housing is electropolished 316 stainless steel, Type 4X and IP66, with a 128 x 64 pixel LCD. The main enclosure is marked II 2 G Ex db mb [ia IIC Ga] IIC T4 Gb and the sensor assembly II 1 G Ex ia IIC T4 Ga. The type certificate is ITS17ATEX101945X and the IECEx certificate is ETL 17.0030X, with conformity to EN 60079-0, EN 60079-1, EN 60079-11 and EN 60079-18 under Directive 2014/34/EU. For North America the approvals are Class I, Division 1, Groups B, C and D; Class II, Division 1, Groups E, F and G; and Class III, Division 1. The intrinsically safe sensor circuit is connected through a B3X triple-redundant barrier.

The transmitter is ordered by code, which sets the number of channels, power type, relays, outputs and certification. The certification options are 316 stainless steel without certificate, FM, ATEX and IECEx for one channel, and ATEX and IECEx for two channels.

Measuring ranges are pH -1 to 15, ORP -1500 to +1500 mV, conductivity 0.055 µS to 2 S, resistivity 0.001 to 20 megohms and chlorine dioxide 0.01 to 20 ppm. The temperature input is -30 to 140 °C. Accuracy is 0.02 pH for pH, ±1 mV for ORP, 2% of range for oxygen, conductivity and resistivity, and ±0.3 °C for temperature. Ambient temperature is -20 to +55 °C for the main enclosure and -20 to +85 °C for the sensor assembly. Dimensions are 14 x 13 x 12.7 cm.

Technical specifications

Sensorsdigital SP3X, 1 or 2 channels
Measured parameterspH, ORP, pION, dissolved oxygen, free and total chlorine, chlorine dioxide, conductivity, resistivity, turbidity
pH range-1 to 15 pH
ORP range-1500 to +1500 mV
Conductivity0.055 µS to 2 S
Resistivity0.001 to 20 megohms
Chlorine dioxide0.01 to 20 ppm
pH / ORP accuracy0.02 pH / ±1 mV
Temperature accuracy±0.3 °C
Outputs4-20 mA, RS485 Modbus RTU, HART (optional)
Relays3 x SPDT (DC power only)
Power supplyloop-powered (24 VDC loop), or 24 VDC
Power consumption4 W
DisplayLCD 128 x 64 pixels
Housing316 stainless steel, Type 4X, IP66
Housing explosion protectionII 2 G Ex db mb [ia IIC Ga] IIC T4 Gb
Sensor explosion protectionII 1 G Ex ia IIC T4 Ga
Ambient temperature (housing)-20 to +55 °C
Dimensions14 x 13 x 12.7 cm

Part numbers

Show all part numbers (5)

LXT380, FCA380, CDA380, B3X, SP3X

Request a price and lead time

LXT 380 Explosion-Protected Liquid Transmitter, Ex db mb [ia IIC Ga] IIC T4 Gb. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which explosion-protection certificates does the LXT 380 hold?

ATEX (ITS17ATEX101945X), IECEx (ETL 17.0030X) and FM. The main enclosure is marked II 2 G Ex db mb [ia IIC Ga] IIC T4 Gb.

Can relays be fitted with loop power?

No. Three SPDT relays are available only with 24 VDC power. The loop-powered version is single channel.

How does the LXT 380 differ from the LXT 330?

The LXT 380 works with SP3X sensors and is available in an explosion-protected version with FM, ATEX and IECEx certification. The LXT 330 with SP3 sensors is intended for areas without explosion hazard.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides