LXT 330 Universal Liquid Transmitter, 1 or 2 Channels, 4-20 mA, Modbus, HART
The LXT 330 takes signals from one or two digital SP3 sensors and measures pH, ORP, specific ion (pION) parameters, dissolved oxygen, chlorine, conductivity, resistivity and turbidity. It has 4-20 mA and Modbus-RTU outputs, with HART as an option, and runs from loop power, 24 VDC or 110/220 VAC.
- Sensors
- digital SP3, 1 or 2 channels
- Measured parameters
- pH, ORP, pION, dissolved oxygen, chlorine, conductivity, resistivity, turbidity
- pH range
- -1.00 to 15.00 pH
- pH accuracy
- 0.02 pH
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The LXT 330 is used for continuous online monitoring of process water at industrial sites without hazardous areas. One transmitter works with any digital SP3 sensor without reprogramming, so there is no need to stock separate instruments for each parameter. The measured quantities are pH, ORP, specific ion measurements (pION), dissolved oxygen, free and total chlorine, conductivity, resistivity and turbidity.
Transmitter and sensor exchange data in both directions. The sensor memory stores the measured parameter, sensor data, serial number and calibration history, and after connection the transmitter sets up its menu and display automatically. Up to two SP3 sensors can be connected to one transmitter, and the galvanic oxygen sensor works only in the single-channel configuration. The first channel can be ordered with an internal amplifier for high-temperature conductivity sensors.
The unit is specified by order code. Power options are a two-wire loop (single channel only), DC without relays or with three relays, and 110/220 VAC without relays or with three relays. Outputs are 4-20 mA with Modbus or HART, or two 4-20 mA outputs with Modbus or HART. Modbus is available only in the AC or DC powered versions. Mounting kits are universal, panel, handrail, and a sunshade for pipe or rail mounting.
The pH range is -1.00 to 15.00 with an accuracy of 0.02 pH, and ORP accuracy is ±1 mV. Conductivity runs from 0.055 µS to 2.00 S with automatic unit selection, and resistivity from 0.001 to 20.00 megohms. Accuracy for oxygen, conductivity and resistivity is 2% of the calibrated range, and turbidity accuracy is 4%. The temperature input is from -30 to 140 °C. The housing is electropolished SS316 (Type 4X, IP66) or polycarbonate (IP65), with an LCD display that is backlit in the AC and DC powered versions.
Ambient temperature is -20 to 60 °C for loop and DC power, and -30 to 85 °C for AC. Relative humidity is 0 to 80% without condensation. The weight is 0.75 kg and the dimensions are 14.48 x 14.48 x 8.89 cm. Modbus defaults to 9600 baud, 8N1 format, with addresses 001 to 247. HART defaults to 1200 baud, 8O1 format, with addresses 01 to 63.
Technical specifications
| Sensors | digital SP3, 1 or 2 channels |
|---|---|
| Measured parameters | pH, ORP, pION, dissolved oxygen, chlorine, conductivity, resistivity, turbidity |
| pH range | -1.00 to 15.00 pH |
| pH accuracy | 0.02 pH |
| ORP accuracy | ±1 mV |
| Conductivity | 0.055 µS to 2.00 S |
| Resistivity | 0.001 to 20.00 megohms |
| Accuracy of oxygen, conductivity, resistivity | 2% of calibrated range |
| Temperature input | -30 to 140 °C |
| Outputs | 4-20 mA, Modbus-RTU, HART (optional) |
| Relays | 3 x SPDT (optional) |
| Power supply | 24 VDC loop, 18-36 VDC, 110/220 VAC |
| Housing | SS316 Type 4X (IP66) or polycarbonate (IP65) |
| Ambient temperature | -20 to 60 °C (loop, DC) |
| Relative humidity | 0–80% non-condensing |
| Weight | 0.75 kg |
| Dimensions | 14.48 x 14.48 x 8.89 cm |
Part numbers
Show all part numbers (3)
LXT330-XX-0X-XX, LXT330-XX-1X-XX, LXT330-XX-2X-XX
Request a price and lead time
LXT 330 Universal Liquid Transmitter, 1 or 2 Channels, 4-20 mA, Modbus, HART. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the LXT 330 be used in a hazardous area?
No, the LXT 330 is intended for process water at sites without hazardous areas. The LXT 380 in the same series has FM, ATEX and IECEx certification for such areas.
Does the transmitter need reconfiguring when the sensor is changed?
No. The transmitter works with any SP3 sensor and sets up its menu automatically from the data stored in the sensor memory.
Which outputs are available with loop power?
The loop-powered version is single channel, and Modbus is not available on it. Modbus works only in the AC or DC powered versions.