
LGA-4000Z TDLAS Gas Analyser, ATEX Zone 1 IIC T6
The LGA-4000Z measures gas concentration by tunable diode laser absorption spectroscopy (TDLAS), either in situ across a process duct or on an extracted sample. It is certified ATEX and IECEx for Zone 1 IIC T6 and has an IP66 enclosure.
- Measuring principle
- TDLAS with wavelength modulation (WMS)
- Measured gases
- C2H2, NH3, CO2, CO, C2H4, HCl, HF, H2S, CH4, O2, H2O
- Optical path length
- 0.6 to 20 m, depending on application
- Linearity
- ±1% FS
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The analyser continuously measures the composition of process and flue gases in chemical, refining, metallurgy and power plants. Depending on the laser configuration, it can determine acetylene (C2H2), ammonia (NH3), carbon dioxide (CO2), carbon monoxide (CO), ethylene (C2H4), hydrogen chloride (HCl), hydrogen fluoride (HF), hydrogen sulphide (H2S), methane (CH4), oxygen (O2) or water vapour (H2O).
Measurement relies on absorption of laser light at a line specific to the chosen gas. A semiconductor laser sends the beam across the flow, a receiver records the weakening signal, and wavelength modulation spectroscopy (WMS) reduces low-frequency noise to improve sensitivity. The optical path is typically 0.6 to 20 m, and the response time is normally under 1 s. Linearity is within ±1% FS, and drift stays below ±1% FS over 6 months.
The in situ version consists of a transmitting unit, a receiving unit, a purge arrangement and a junction box. It is mounted on a flange with a root valve directly on the pipeline, so no sample is extracted. The transmitter housing is 170 mm in diameter and 331 mm high, and the receiver is 170 mm by 347.5 mm. Housings are 6061 aluminium alloy and SUS304 stainless steel, and the optical window is N-BK7 glass. The extractive LGA-4000Z version is a panel-mounted instrument for indoor use with a sample cell and filter, working with a sample pressure of 0.8 to 1.2 bar, a flow of 0.5 to 5 L/min and a temperature up to 200 °C.
For purging the optics, air or nitrogen at 0.3 to 0.8 MPa is required. The analyser provides two isolated 4 to 20 mA outputs, two Form-C relay contacts rated 1 A at 24 V DC, and RS-485 and RS-232 interfaces. It also accepts two 4 to 20 mA inputs for pressure and temperature compensation and runs from 24 V DC at 10 W. The ambient range is -20 to 60 °C with humidity up to 90% RH, and the device carries Ex db op is IIC T6 Gb and Ex tb op is IIIC T80 °C Db markings. Maintenance means cleaning the optical window, and calibration is performed offline with a 0.5 m calibration gas cell, no more than twice a year.
Technical specifications
| Measuring principle | TDLAS with wavelength modulation (WMS) |
|---|---|
| Measured gases | C2H2, NH3, CO2, CO, C2H4, HCl, HF, H2S, CH4, O2, H2O |
| Optical path length | 0.6 to 20 m, depending on application |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Response time | typically under 1 s |
| Drift | under ±1% FS over 6 months |
| Purge gas | air or nitrogen, 0.3 to 0.8 MPa |
| Analogue outputs | 2 × 4 to 20 mA, isolated, load up to 750 Ω |
| Switch outputs | 2 Form-C relays, 1 A at 24 V DC |
| Interfaces | RS-485 / RS-232 |
| Analogue inputs | 2 × 4 to 20 mA (pressure and temperature compensation) |
| Power | 24 V DC, 10 W |
| Ambient temperature | -20 to 60 °C |
| Explosion protection | Ex db op is IIC T6 Gb; Ex tb op is IIIC T80 °C Db |
| Certifications | ATEX, IECEx, Zone 1 IIC T6 |
| Ingress protection | IP66 |
| Functional safety | SC2, type B, up to SIL2 (HFT=0) |
Part numbers
Show all part numbers (2)
LGA-4000Z, LGA4000Z Extractive
Request a price and lead time
LGA-4000Z TDLAS Gas Analyser, ATEX Zone 1 IIC T6. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the LGA-4000Z need a sample extraction system?
The in situ version is mounted on a pipeline flange and measures the gas in the stream without extraction. The extractive version is a panel-mounted instrument for indoor use that needs a sample cell and filter.
Which signals does the analyser send to the control system?
It provides two isolated 4 to 20 mA outputs, two Form-C relay contacts rated 1 A at 24 V DC, and RS-485 and RS-232 digital interfaces.
Can the analyser be installed in a hazardous area?
Yes, the housing is certified to ATEX and IECEx for Zone 1 IIC T6, carries the Ex db op is IIC T6 Gb marking and has IP66 protection.
Similar equipment from other manufacturers






