INSTA TRACE micro-fuel cell oxygen sensor for trace O2 below 1 ppm
INSTA TRACE is a micro-fuel electrochemical cell for trace oxygen analysers. After replacement it reads below 1 ppm O2 within 15 minutes, whereas a conventional cell takes 6 to 24 hours to recover. Retrofit kits are available for several analyser series.
- Type
- micro-fuel electrochemical cell
- Measured quantity
- trace oxygen (O2)
- Measuring limit
- below 1 ppm O2
- Reading available after fitting
- within 15 minutes
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The INSTA TRACE cell is used in trace oxygen analysers that monitor gas purity in process lines. Its main benefit appears where an analyser cannot be taken out of service for long, for example in air separation plants.
When a standard electrochemical trace oxygen cell is replaced, the new cell is taken out of its barrier bag and exposed to atmospheric air. Its electrolyte takes up dissolved oxygen, and the longer the exposure lasts, the longer the cell needs to recover. A typical recovery after replacement runs from 6 to 24 hours, and the process can be interrupted for six hours or more.
The INSTA TRACE design is patented and reduces this recovery period from hours to minutes. The sensor gives meaningful readings below 1 ppm O2 within 15 minutes of fitting. During the change there is no need to divert unanalysed product, switch to a backup liquid supply on the air separation unit, or send the flow through another analyser.
Kits are supplied for existing instruments, one for each analyser series: the 3000T, 316, 311 and 3160. Each series has its own kit number, so the analyser model in which the sensor will run must be stated when ordering. The replacement follows the normal maintenance routine. Once fitted, the sensor reaches working level within minutes, and monitoring of oxygen impurities in the product resumes without a long gap in measurement, which limits the effect of a planned change on plant operation and product losses.
Technical specifications
| Type | micro-fuel electrochemical cell |
|---|---|
| Measured quantity | trace oxygen (O2) |
| Measuring limit | below 1 ppm O2 |
| Reading available after fitting | within 15 minutes |
| Recovery of a standard sensor | 6 to 24 hours |
| Kit for 3000T series | C-71792-A |
| Kit for 316 series | C-71792-B |
| Kit for 311 series | C-71792-C |
| Kit for 3160 series | C-71792-D |
Part numbers
Show all part numbers (4)
C-71792-A, C-71792-B, C-71792-C, C-71792-D
Request a price and lead time
INSTA TRACE micro-fuel cell oxygen sensor for trace O2 below 1 ppm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How long does the sensor need after replacement?
The INSTA TRACE gives readings below 1 ppm O2 within 15 minutes of fitting, while a conventional cell recovers in 6 to 24 hours.
Which analysers have retrofit kits?
Kits are available for the 3000T, 316, 311 and 3160 series, with kit numbers from C-71792-A to C-71792-D.
Why does a conventional sensor take so long to recover?
During replacement the cell is exposed to air, and its electrolyte absorbs dissolved oxygen. The longer the exposure, the longer the recovery takes.