Industrial RTD Temperature Sensors, -200 to 650 °C, DIN Class A and B
Industrial resistance temperature detectors for accurate, repeatable measurement of air, gas, liquid and surface temperatures between -200 and 650 °C. Accuracy is ±0.06% for DIN Class A and ±0.12% for Class B, both referenced to 0 °C, with several constructions and the SERIES 5750 transmitter available.
- Type
- resistance temperature detector (RTD)
- Temperature range
- -200 to 650 °C
- Class A accuracy (DIN)
- ±0.06%, reference point 0 °C
- Class B accuracy (DIN)
- ±0.12%, reference point 0 °C
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Sensors of this line are used in food equipment such as ovens, grills and fryers, in textile production, plastics processing, petrochemical plants and semiconductor manufacturing. They measure the temperature of air, gases, liquids and exhaust gases, and are also fitted to bearing housings and gearboxes. A separate application area is the control of humidity and temperature in fuel cells and their ancillary systems.
The sensing elements are built without mechanical stress in the structure. The reading is stable, and elements from different batches are interchangeable without recalibration. A high signal-to-noise ratio improves transmission accuracy and allows the distance between the sensor and the secondary instrument to be increased. The temperature coefficient (alpha) is tightly controlled, and insulation resistance exceeds the requirements of DIN-IEC-751, which reduces self-heating and improves sensitivity.
Style RB has standard insulated leads and an internal heat-transfer plate for a fast response, epoxy sealing against moisture and pull-out, a sheath of 316 stainless steel, and a range from -50 to 260 °C. Style RC ends in a plug or socket, with a 316 sheath and the same range. Style RF, with metal transitions and flexible mineral insulation, covers -200 to 650 °C. Style RW is a washer-type sensor with a stainless tube and a ring terminal for screw fixing, from -50 to 260 °C.
For protection there are Style RT sheaths with mineral insulation, in diameters from 0.125 to 0.250 inch, with spring loading to keep the sensor in constant contact and a choice of terminal heads. A complete assembly can also be supplied. The SERIES 5750 converter in a low-profile housing accepts Pt100 and Pt1000 signals in a 3-wire or 4-wire circuit and outputs 4 to 20 mA. Its input span runs from -200 to +1000 °C, linearity is ±0.1%, and the calibration error is no more than ±0.2 °C or ±0.1%, with operating conditions between -40 and +85 °C.
Technical specifications
| Type | resistance temperature detector (RTD) |
|---|---|
| Temperature range | -200 to 650 °C |
| Class A accuracy (DIN) | ±0.06%, reference point 0 °C |
| Class B accuracy (DIN) | ±0.12%, reference point 0 °C |
| Style RB | insulated leads, 316 sheath, -50 to 260 °C |
| Style RC | plug or socket, 316 sheath, -50 to 260 °C |
| Style RF | metal transitions, mineral insulation, -200 to 650 °C |
| Style RW | washer-type sensor with ring terminal, -50 to 260 °C |
| Style RT sheaths | diameter 0.125–0.250 inch, spring loaded |
| SERIES 5750 converter | Pt100/Pt1000, 3- or 4-wire, 4–20 mA output |
| SERIES 5750 input range | -200 to +1000 °C |
| SERIES 5750 linearity | ±0.1% |
| SERIES 5750 operating conditions | -40 to +85 °C |
| Standards | DIN-IEC-751, IEC 60751 |
Request a price and lead time
Industrial RTD Temperature Sensors, -200 to 650 °C, DIN Class A and B. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which construction should be chosen for temperatures above 260 °C?
Style RF with flexible mineral insulation works from -200 to 650 °C. The RB, RC and RW types are limited to the range -50 to 260 °C.
Is recalibration needed when a sensing element is replaced?
No. The sensing elements are built without mechanical stress, so elements from different batches are interchangeable without recalibration.
How can the sensor signal be sent to a controller as a current signal?
The SERIES 5750 converter accepts Pt100 or Pt1000 in a 3- or 4-wire circuit and outputs 4 to 20 mA with ±0.1% linearity.