HTZ Humidity and Temperature Transmitter with HART and Two Analogue Outputs
The HTZ measures relative humidity and temperature in ducts, hard-to-reach places and rooms. It is programmed via HART, has a local and remote display, and provides two analogue outputs for humidity, temperature or dew point.
- Type
- relative humidity and temperature transmitter
- Humidity accuracy
- ±0.75%
- Outputs
- two analogue, configurable
- Output variables
- humidity, temperature, dew point
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The HTZ is designed for continuous monitoring of air humidity and temperature where deviations in conditions lead to equipment failure. A typical case is a data centre, where servers run round the clock and cooling and humidification must stay within set limits without interruption. The same measurements are needed in power generation, chemicals, oil and gas extraction and refining, semiconductor and microelectronics production, pharmaceuticals and biotechnology, pulp and paper, mining and metal refining, water treatment and food production.
The sensor head has several mounting options. It can be fitted into a duct as a duct-mounted assembly, or taken out on a flexible probe to reach measuring points in tight or hard-to-access spaces. For general room monitoring the sensor is wall-mounted.
Relative humidity accuracy is ±0.75%. The transmitter has two analogue outputs, each of which can be set independently to carry humidity, temperature or calculated dew point. One device therefore covers two control channels in a control system or a building services monitoring system.
Setup is done over HART, so output ranges, variable assignments and other parameters can be changed from a communicator or a higher-level system without opening the housing. A local display is fitted to the unit, and a remote display can be connected, which is useful when the sensor sits in a duct or above a ceiling.
When ordering, specify the sensor mounting (duct, flexible probe or wall), the variables required on the outputs, and whether a remote display is needed.
Technical specifications
| Type | relative humidity and temperature transmitter |
|---|---|
| Humidity accuracy | ±0.75% |
| Outputs | two analogue, configurable |
| Output variables | humidity, temperature, dew point |
| Configuration | HART |
| Indication | local display, remote display |
| Mounting | duct assembly, flexible probe, wall |
Part numbers
Show all part numbers (1)
HTZ
Request a price and lead time
HTZ Humidity and Temperature Transmitter with HART and Two Analogue Outputs. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What can the HTZ analogue outputs carry?
Each of the two outputs can be set to humidity, temperature or dew point. The assignment is changed over HART.
How is the sensor installed?
In a duct as a duct-mounted assembly, on a flexible probe for hard-to-reach points, or on a wall for measurement in a room.
What is the humidity measurement accuracy?
The accuracy of relative humidity measurement is ±0.75%.