International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

HIT HART signal isolator, 4-20 mA, 24 Vdc, DIN rail

The HIT isolates a 4-20 mA loop and passes HART data from the field transmitter to host systems and back. It protects against surges and spikes up to 1500 Vrms. Supply is 24 Vdc, 117 Vac or 230 Vac, in a DIN rail housing.

Input
4-20 mA, one input
Output
4-20 mA, one output
Power supply
24 Vdc, 117 Vac or 230 Vac, 4-wire
HART
pass-through: yes

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Protection and isolation of loops come with the HIT HART signal isolator, which also passes HART data from the field transmitter to host systems and vice versa. It takes a 4-20 mA input and gives a 4-20 mA output, and it guards against surges and spikes up to 1500 Vrms.

The universal DIN-style housing fits 32 mm G-type and 35 mm Top Hat rails. There is one input and one output, both fixed, so no set-up is needed. The unit has no integral display, alarm or relay output, and it is not intended for use in safety instrumented systems (SIS).

Power is 4-wire line/mains at 24 Vdc, 117 Vac or 230 Vac, depending on the version. The base version is HIT/4-20mA/4-20mA/24DC [DIN]. The family includes [DIN] and [FLB] housing versions and the options -IZ100, -RF and -TX, and the full list of order codes runs to 48 versions.

Hazardous-area certification is CSA General Location, Non-Incendive/Div. 2, Zone 2. The unit is RoHS compliant.

Technical specifications

Input4-20 mA, one input
Output4-20 mA, one output
Power supply24 Vdc, 117 Vac or 230 Vac, 4-wire
HARTpass-through: yes
Surge protectionup to 1500 Vrms
Set-upfixed input/output
For SISno
Rails32 mm G-type, 35 mm Top Hat
Options-IZ100, -RF, -TX
Housing versions[DIN], [FLB]
Hazardous areasCSA General Location, Non-Incendive/Div. 2, Zone 2

Part numbers

Show all part numbers (1)

HIT/4-20mA/4-20mA/24DC [DIN]

How it compares with similar models

ParameterHIT HART signal isolator, 4-20 mA, 24 Vdc, DIN railECT-DIN 15 mm signal isolator and converter, 1-5 V to 4-20 mAECT 4-wire signal isolator, converter and splitter, 4-20 mA, 24 Vdc, 1 or 2 outputsTCM temperature concentrator module, 16 channels, HART, 15-30DC, intrinsically safe, DIN rail
Input4-20 mA, one input1-5 V4-20 mA, one input—
Output4-20 mA, one output4-20 mA, one output—HART digital only
Power supply24 Vdc, 117 Vac or 230 Vac, 4-wire12-42 Vdc, 2-wire, from the output loop24 Vdc, 4-wire—
Options-IZ100, -RF, -TX-RF, -VTD, -EM, FLB2-TX, -RF, -EM, -VTD, FLB2—
Hazardous areasCSA General Location, Non-Incendive/Div. 2, Zone 2UL, Class I, Div. 2, Groups A-D, T4; Zone 2UL, Class I, Div. 2, Zone 2—

Request a price and lead time

HIT HART signal isolator, 4-20 mA, 24 Vdc, DIN rail. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the HIT pass the HART signal?

Yes, HART data pass from the field transmitter to the host system and in the opposite direction.

What supply voltage does the HIT use?

4-wire power at 24 Vdc, 117 Vac or 230 Vac, depending on the version.

Can the HIT be used in an SIS?

No, it is not intended for safety instrumented systems.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides