HIT HART signal isolator, 4-20 mA, 24 Vdc, DIN rail
The HIT isolates a 4-20 mA loop and passes HART data from the field transmitter to host systems and back. It protects against surges and spikes up to 1500 Vrms. Supply is 24 Vdc, 117 Vac or 230 Vac, in a DIN rail housing.
- Input
- 4-20 mA, one input
- Output
- 4-20 mA, one output
- Power supply
- 24 Vdc, 117 Vac or 230 Vac, 4-wire
- HART
- pass-through: yes
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Protection and isolation of loops come with the HIT HART signal isolator, which also passes HART data from the field transmitter to host systems and vice versa. It takes a 4-20 mA input and gives a 4-20 mA output, and it guards against surges and spikes up to 1500 Vrms.
The universal DIN-style housing fits 32 mm G-type and 35 mm Top Hat rails. There is one input and one output, both fixed, so no set-up is needed. The unit has no integral display, alarm or relay output, and it is not intended for use in safety instrumented systems (SIS).
Power is 4-wire line/mains at 24 Vdc, 117 Vac or 230 Vac, depending on the version. The base version is HIT/4-20mA/4-20mA/24DC [DIN]. The family includes [DIN] and [FLB] housing versions and the options -IZ100, -RF and -TX, and the full list of order codes runs to 48 versions.
Hazardous-area certification is CSA General Location, Non-Incendive/Div. 2, Zone 2. The unit is RoHS compliant.
Technical specifications
| Input | 4-20 mA, one input |
|---|---|
| Output | 4-20 mA, one output |
| Power supply | 24 Vdc, 117 Vac or 230 Vac, 4-wire |
| HART | pass-through: yes |
| Surge protection | up to 1500 Vrms |
| Set-up | fixed input/output |
| For SIS | no |
| Rails | 32 mm G-type, 35 mm Top Hat |
| Options | -IZ100, -RF, -TX |
| Housing versions | [DIN], [FLB] |
| Hazardous areas | CSA General Location, Non-Incendive/Div. 2, Zone 2 |
Part numbers
Show all part numbers (1)
HIT/4-20mA/4-20mA/24DC [DIN]
How it compares with similar models
| Parameter | HIT HART signal isolator, 4-20 mA, 24 Vdc, DIN rail | ECT-DIN 15 mm signal isolator and converter, 1-5 V to 4-20 mA | ECT 4-wire signal isolator, converter and splitter, 4-20 mA, 24 Vdc, 1 or 2 outputs | TCM temperature concentrator module, 16 channels, HART, 15-30DC, intrinsically safe, DIN rail |
|---|---|---|---|---|
| Input | 4-20 mA, one input | 1-5 V | 4-20 mA, one input | — |
| Output | 4-20 mA, one output | 4-20 mA, one output | — | HART digital only |
| Power supply | 24 Vdc, 117 Vac or 230 Vac, 4-wire | 12-42 Vdc, 2-wire, from the output loop | 24 Vdc, 4-wire | — |
| Options | -IZ100, -RF, -TX | -RF, -VTD, -EM, FLB2 | -TX, -RF, -EM, -VTD, FLB2 | — |
| Hazardous areas | CSA General Location, Non-Incendive/Div. 2, Zone 2 | UL, Class I, Div. 2, Groups A-D, T4; Zone 2 | UL, Class I, Div. 2, Zone 2 | — |
Request a price and lead time
HIT HART signal isolator, 4-20 mA, 24 Vdc, DIN rail. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the HIT pass the HART signal?
Yes, HART data pass from the field transmitter to the host system and in the opposite direction.
What supply voltage does the HIT use?
4-wire power at 24 Vdc, 117 Vac or 230 Vac, depending on the version.
Can the HIT be used in an SIS?
No, it is not intended for safety instrumented systems.
Similar equipment from other manufacturers