ECT-DIN 15 mm signal isolator and converter, 1-5 V to 4-20 mA
The ECT-DIN in a narrow 15 mm metal housing isolates a 1-5 V signal and converts it to 4-20 mA. It draws power from the output loop at 12-42 Vdc, isolates up to 1500 Vrms and operates from -40°C to +85°C.
- Input
- 1-5 V
- Output
- 4-20 mA, one output
- Power supply
- 12-42 Vdc, 2-wire, from the output loop
- Isolation
- up to 1500 Vrms
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A solid metal DIN-style housing only 15 mm wide holds the ECT-DIN isolator and converter. The ECT/1-5V/4-20mA/12-42DC [DIN] version takes a 1-5 V input and gives a standard 4-20 mA output. It is a 2-wire unit that derives its operating power from the output side of the loop, where the receiving device such as a DCS normally supplies 12-42 Vdc.
The narrow width fits more isolators into the same space without giving up RFI/EMI protection or the -40°C to +85°C operating range, so the unit needs no climate-controlled room. Humidity may be 0-95%, non-condensing.
Signal isolation up to 1500 Vrms stops ground loops, motor noise and other electrical interference from reaching process signals. Conversion lets field instruments interface directly with an indicator, recorder, DCS, PLC or SCADA system. The ECT family also covers splitting one signal between two systems, boosting a signal on an overburdened loop, resolving "bucking" power supplies and stepping dangerous high-voltage signals down to safer levels.
Input and output are fixed, so no set-up is needed. The options are -RF (enhanced RFI/EMI filtering), -VTD (standard factory calibration), -EM (externally mounted input transformer) and FLB2 (externally mounted flange).
It snaps onto 32 mm G-type (EN50035) and 35 mm Top Hat (EN50022) rails. UL approval covers ordinary and hazardous locations, Class I, Division 2, Groups A, B, C and D, T4 (Non-Incendive/Div. 2, Zone 2), but not units fitted with the -RF option. The unit conforms to EMC Directive 2014/30/EU (EN 61326) and Low Voltage Directive 2014/35/EU (EN 61010), and is RoHS compliant.
Technical specifications
| Input | 1-5 V |
|---|---|
| Output | 4-20 mA, one output |
| Power supply | 12-42 Vdc, 2-wire, from the output loop |
| Isolation | up to 1500 Vrms |
| Set-up | fixed input/output |
| Housing width | 15 mm, metal |
| Operating range | -40°C to +85°C |
| Humidity | 0-95%, non-condensing |
| Options | -RF, -VTD, -EM, FLB2 |
| Rails | 32 mm G-type, 35 mm Top Hat |
| Hazardous areas | UL, Class I, Div. 2, Groups A-D, T4; Zone 2 |
Part numbers
Show all part numbers (1)
ECT/1-5V/4-20mA/12-42DC [DIN]
How it compares with similar models
| Parameter | ECT-DIN 15 mm signal isolator and converter, 1-5 V to 4-20 mA | ECT 4-wire signal isolator, converter and splitter, 4-20 mA, 24 Vdc, 1 or 2 outputs | HIT HART signal isolator, 4-20 mA, 24 Vdc, DIN rail | SIY PC-programmable signal isolator and converter, input up to 55mA or 11V, 4-20mA output |
|---|---|---|---|---|
| Input | 1-5 V | 4-20 mA, one input | 4-20 mA, one input | programmable, any range within -2.5 to 55mA or -0.5 to 11V |
| Output | 4-20 mA, one output | — | 4-20 mA, one output | 4-20mA, isolated |
| Power supply | 12-42 Vdc, 2-wire, from the output loop | 24 Vdc, 4-wire | 24 Vdc, 117 Vac or 230 Vac, 4-wire | — |
| Options | -RF, -VTD, -EM, FLB2 | -TX, -RF, -EM, -VTD, FLB2 | -IZ100, -RF, -TX | — |
| Hazardous areas | UL, Class I, Div. 2, Groups A-D, T4; Zone 2 | UL, Class I, Div. 2, Zone 2 | CSA General Location, Non-Incendive/Div. 2, Zone 2 | — |
Request a price and lead time
ECT-DIN 15 mm signal isolator and converter, 1-5 V to 4-20 mA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What signals does the ECT-DIN convert?
A 1-5 V input to a 4-20 mA output, powered from the output loop at 12-42 Vdc.
Which rails does it mount on?
32 mm G-type (EN50035) and 35 mm Top Hat (EN50022) rails, in a housing 15 mm wide.
Does the UL approval apply with the -RF option?
No, the UL certification does not apply to units fitted with the -RF option.