TCM temperature concentrator module, 16 channels, HART, 15-30DC, intrinsically safe, DIN rail

The TCM has 16 channels, each configurable for RTD, T/C, millivolt or resistance/potentiometer signals, and sends the data over HART. Intrinsically safe and non-incendive, 15-30DC supply, DIN rail housing.

Type
Temperature concentrator module, 16 channels
Inputs
16 channels, each configurable: RTD, T/C, mV, resistance/potentiometer
RTD
2-, 3-, 4-wire; Pt, Cu, Ni
Thermocouples
J, K, E, T, R, S, N, B, C

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TCM Temperature Concentrator Module has 16 channels that can be individually configured to accept an RTD, T/C, millivolt and/or resistance/potentiometer signal. It is approved for intrinsic safety and non-incendive use. All data is transmitted over HART to a HART host, so a dedicated transmitter and twisted wire pair, or expensive sensor extension wire, is not needed for each measurement.

The inputs accept any combination of RTD (2-, 3-, 4-wire; Pt, Cu, Ni), thermocouples J, K, E, T, R, S, N, B and C, resistance/potentiometer (0-4000 ohms) and millivolt (-50 to 1000mV) signals. In intrinsically safe installations only one isolated I.S. barrier is needed for all 16 points.

For MODBUS RTU the TCM is used with the HMC HART-to-MODBUS converter, and for MODBUS/TCP or HART-IP with the HES HART-to-Ethernet Gateway System. The HMC and the single channel HES can communicate with two TCMs only. The module can be installed in Class I, II, III, Division 1 (Zone 0/1) hazardous areas.

The supply is 15-30DC and the digital output is HART only. The metal housing is RFI/EMI resistant and snaps onto DIN-style rails. Configuration is from a PC over a USB cable. There is no integral display and no alarm or relay output, and the module is not for use in SIS. It is RoHS compliant.

Technical specifications

TypeTemperature concentrator module, 16 channels
Inputs16 channels, each configurable: RTD, T/C, mV, resistance/potentiometer
RTD2-, 3-, 4-wire; Pt, Cu, Ni
ThermocouplesJ, K, E, T, R, S, N, B, C
Resistance/potentiometer0-4000 ohms
Millivolt-50 to 1000mV
OutputHART digital only
Power15-30DC, intrinsically safe
HousingDIN rail mount, DIN rail enclosure
ConfigurationPC, USB cable
Integral displayNo
Alarm / relay outputNo
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2, Intrinsically-Safe
For use in SISNo
RoHSYes

Part numbers

Show all part numbers (1)

TCM/TPRG/HART/15-30DC [DIN]

How it compares with similar models

ParameterTCM temperature concentrator module, 16 channels, HART, 15-30DC, intrinsically safe, DIN railTHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DCTRY PC-programmable isolated temperature transmitter, 4-20mA, 10-42DC, DIN railTHZ3 associated IS dual input HART temperature transmitter (-AIS), 4-20mA, DIN rail
TypeTemperature concentrator module, 16 channelsDual input HART temperature transmitter for DIN rail mountingPC-programmable isolated temperature transmitterDual input associated IS HART temperature transmitter
OutputHART digital only4-20mA, isolated, linear, with HART4-20mA, linear, scalable, 4-20mA only4-20mA with HART
Power15-30DC, intrinsically safe12-42DC, 2-wire, loop powered10-42DC, 2-wire, loop powered12-42DC, 2-wire, loop powered
ConfigurationPC, USB cablePC, USB cable, HARTPC, USB cablePC, USB cable, HART
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2, Intrinsically-SafeNon-Incendive/Div. 2, Zone 2—Non-Incendive/Div. 2, Zone 2, Associated Intrinsically-Safe

Request a price and lead time

TCM temperature concentrator module, 16 channels, HART, 15-30DC, intrinsically safe, DIN rail. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which signals can a TCM channel accept?

RTD, T/C, millivolt or resistance/potentiometer. Each of the 16 channels is configured individually.

How can the data reach a MODBUS or Ethernet host?

Over MODBUS RTU through the HMC HART-to-MODBUS converter, or over MODBUS/TCP and HART-IP through the HES HART-to-Ethernet Gateway System.

Where can the TCM be installed?

In Class I, II, III, Division 1 (Zone 0/1) hazardous areas, thanks to the intrinsically safe design. One isolated I.S. barrier serves all 16 points.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides