3–8 Inch Flange Circulation Heater without Baffles, Sheath up to 870 ºC
Complete assembly for heating forced-circulation air, gases and liquids, combining an ANSI flange heater block with a vessel that has no internal baffles. It takes WATROD or FIREBAR elements and can be fitted in-line or on a side arm.
- Type
- circulation heater with ANSI flange heating block
- Flange size
- 3–8 inches
- Internal baffles
- none
- Medium
- air, gases, liquids with forced circulation
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
This unit is used to heat a medium moved by a pump or fan, such as process air, gases, water, heat transfer fluids and liquid products. It suits sites where electric heating has to be built into a pipeline without designing a separate heat exchanger from scratch.
The supply covers everything needed for installation: heating elements, pressure vessel, insulation, terminal box, mounting brackets and inlet and outlet connections. The ANSI flange heater, sized from 3 to 8 inches, bolts onto the flange of the vessel. This version has no internal baffles, so the medium flows past tubular WATROD or FIREBAR elements, giving fast response and even heat distribution.
The sheath material sets the upper temperature limit: 650 ºC (1200 ºF) for 316 Stainless Steel, 870 ºC (1600 ºF) for Alloy 800/400 and 400 ºC (750 ºF) for steel. The maximum watt density is 18.6 W/cm^2 (120 W/in^2) for every sheath material.
Units are built to the customer's specification. The variables are sheath material, power, size, vessel material in carbon steel or 316 stainless steel, pressure rating, terminal box layout and controls. The supply is three-phase AC with earthing, at 50 or 60 Hz. Temperature is monitored by 3-wire RTDs. The vessel is designed and made to ASME VIII Div. 1 and holds Directive 2014/68/EU (PED) certification. In hazardous areas the temperature class is set as T2, T3 or T4, and the terminal box comes in painted carbon steel or 316 stainless steel. To size the unit we need the medium, inlet temperature, working pressure and flow rate.
Technical specifications
| Type | circulation heater with ANSI flange heating block |
|---|---|
| Flange size | 3–8 inches |
| Internal baffles | none |
| Medium | air, gases, liquids with forced circulation |
| Heating elements | WATROD or FIREBAR |
| Sheath 316 Stainless Steel | up to 650 ºC (1200 ºF) |
| Sheath Alloy 800/400 | up to 870 ºC (1600 ºF) |
| Sheath Steel | up to 400 ºC (750 ºF) |
| Max. watt density | 18.6 W/cm^2 (120 W/in^2) |
| Vessel materials | carbon steel, 316 stainless steel |
| Power supply | 3-phase AC, 50 or 60 Hz |
| Sensors | 3-wire RTDs |
| Temperature class | none, T2, T3 or T4 |
| Compliance | ASME VIII Div. 1, Directive 2014/68/EU (PED) |
Request a price and lead time
3–8 Inch Flange Circulation Heater without Baffles, Sheath up to 870 ºC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How does this version differ from the one with baffles?
The vessel has no internal baffles. The rest of the assembly, the sheath materials and the temperature limits are the same.
What watt density can the heating elements take?
The maximum is 18.6 W/cm^2, or 120 W/in^2, for all sheath materials.
Which temperature sensors are fitted?
As standard, 3-wire RTDs are fitted for process and limit temperature control.