CPMS cathodic protection rectifier monitor, Modbus RTU and Modbus/TCP

CPMS digitises the signals from one or two cathodic protection rectifiers and sends them to SCADA over MODBUS RTU or Ethernet MODBUS/TCP. It suits remote pipeline sites where there is no RTU or industrial controller beside the rectifier.

Type
cathodic protection rectifier monitoring system
Rectifiers monitored
1 or 2
Rectifier output voltage
0-100 V DC
Current (metering shunt)
0-100 mV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Rectifiers in cathodic protection need constant checking, but some sit where there is no RTU or industrial controller through which their signals could reach the network. The CPMS is intended for these points: it measures every signal from the rectifier and passes them to SCADA in digital form. Applications include upstream oil and gas, refining, power generation and transmission, chemical manufacturing, and water and wastewater treatment.

The system accepts the usual set of rectifier signals: a DC output voltage of 0-100 V, a current through a metering shunt giving 0-100 mV, a structure-to-reference electrode potential from -5 V through 0 to +5 V, and a rectifier temperature signal of 4-20 mA. Rectifiers usually have redundant AC feeds, so the state of each feed breaker is brought into the system as a discrete input.

One CPMS can be set up for one or two rectifiers. Measured values are written to MODBUS registers and read over MODBUS RTU serial or MODBUS/TCP over Ethernet. Both channels run at the same time, so data can go to SCADA and to a local system together. Configuration is carried out through a web browser, which takes little time and needs no separate software on the engineer's workstation.

The GPS option provides accurate time. With GPS-referenced time, groups of rectifiers can be switched off simultaneously, which allows the pipeline potential to be measured more accurately without the influence of protection current.

Technical specifications

Typecathodic protection rectifier monitoring system
Rectifiers monitored1 or 2
Rectifier output voltage0-100 V DC
Current (metering shunt)0-100 mV
Structure to reference electrode potential-5 V … 0 … +5 V
Rectifier temperature4-20 mA
Discrete inputscircuit breakers of redundant AC feeds
CommunicationMODBUS RTU (serial) and Ethernet MODBUS/TCP at the same time
Configurationthrough a web browser
OptionsGPS time

Part numbers

Show all part numbers (1)

CPMS

Request a price and lead time

CPMS cathodic protection rectifier monitor, Modbus RTU and Modbus/TCP. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many rectifiers can one CPMS monitor?

One unit is set up for one or two rectifiers. For each one it measures the voltage, the current through the shunt, the potential and the temperature.

How is the data sent to SCADA?

Values are stored in MODBUS registers and read over MODBUS RTU or Ethernet MODBUS/TCP, with both channels running at the same time.

What is the GPS option for?

GPS gives accurate time, so groups of rectifiers can be switched off in step, which allows a more precise measurement of the pipeline potential.