International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

CMFA-P2000 portable analyser for premix gas and flue gas, O2 and excess fuel

The CMFA-P2000 combines in one portable housing an analyser for the mixture feeding a burner and an oxygen analyser for flue gases. It is built for dual combustion monitoring at container glass plants and in glass fibre production. The measuring element is a zirconium oxide cell with open platinum electrodes.

Range
from 100% to 0.1% excess O2 and from 0.1% to 50% excess fuel
Accuracy O2
± 2% of reading or ± 0.1% O2, whichever is greater
Accuracy fuel
± 5% of reading or ± 0.25% excess fuel, whichever is greater
Repeatability
± 0.2% of reading

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The instrument is used at container glass plants and in glass fibre production, on forehearths, melting tanks, flame treating lines and in furnace atmosphere control. Typical tasks are spot measurements in a glass melting tank, setting up mixing stations for forehearths, and analysis of flue gases and of the mixture feeding a burner, under conditions of excess air or excess fuel.

In flue gas mode the CMFA-P2000 measures excess O2 after combustion. In premix mode it determines the air/fuel ratio in open flame, where flue gas analysis is impossible, and it works with both excess fuel and excess air. This method gives better accuracy than measuring O2 or combustibles in the mixture directly.

The analyser has two parts that can be separated, and the operator reads the values on the control unit while adjusting the mixture and combustion air valves from a distance. A built-in compressor feeds an ejector and draws gas at a draught of up to 6 inches of water, so a mixture sample can be taken at low flow and flue gases can be drawn under draught. The sample flow is 1 L/min for flue gases and 0.47 L/min for the mixture.

The display is a vacuum fluorescent unit with four lines of 20 characters. One isolated current output of 4-20, 0-20, 20-4 or 20-0 mA, scaled and with a load of up to 1200 ohms, carries excess oxygen, excess fuel, a combined scale, combustibles, the fuel to oxidant ratio, cell temperature, or thermocouple or cell millivolts. Drift is less than 0.1% of the cell signal per month.

The control unit works from -10 to 47 °C, while the sensor section works from -20 to 37.8 °C, at 10% to 90% relative humidity without condensation and up to 2000 m altitude. Flue gas inlet temperature ranges from -18 to 1100 °C, and the mixture inlet from 0 to 50 °C. Sample pressure is up to 10 psig (68.95 kPa). The instrument meets EN 61010-1, UL 3101-1 and CAN/CSA 22.2 No. 1010.1-92, with overvoltage category II and pollution degree 2. Dimensions are 27.3 x 45.7 x 40.7 cm and the weight is 19.9 kg.

Technical specifications

Rangefrom 100% to 0.1% excess O2 and from 0.1% to 50% excess fuel
Accuracy O2± 2% of reading or ± 0.1% O2, whichever is greater
Accuracy fuel± 5% of reading or ± 0.25% excess fuel, whichever is greater
Repeatability± 0.2% of reading
Response time O2 (63% / 90%)under 18 s / under 22 s
Response time fuel (63% / 90%)under 17 s / under 63 s
Driftless than 0.1% of cell signal per month
Sample flow1 L/min (flue gases); 0.47 L/min (mixture)
Sample pressureup to 10 psig (68.95 kPa)
Sample temperatureflue gases from -18 to 1100 °C; mixture from 0 to 50 °C
Analogue outputisolated, 4-20 / 0-20 / 20-4 / 20-0 mA, up to 1200 ohms
Alarm contacts0.5 A, 30 V, 10 VA
Power115 VAC ± 10%, 747 VA max; 230 VAC ± 10%, 2222 VA max, 50-60 Hz
Ambient temperaturecontrol unit from -10 to 47 °C; sensor from -20 to 37.8 °C
Built-in compressordraws gas at a draught of up to 6 inches of water
Dimensions27.3 x 45.7 x 40.7 cm
Weight19.9 kg

Request a price and lead time

CMFA-P2000 portable analyser for premix gas and flue gas, O2 and excess fuel. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can flue gases be drawn at a draught?

Yes. The built-in compressor feeds an ejector and draws gas at a draught of up to 6 inches of water.

What is the maximum flue gas inlet temperature?

Flue gas samples are accepted from -18 to 1100 °C, and mixture samples from 0 to 50 °C.

How heavy is the instrument?

It weighs 19.9 kg and measures 27.3 x 45.7 x 40.7 cm.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides