Flange Circulation Heaters, 10 to 14 inch Flanges, for Air, Gases and Liquids
A circulation heater combines a flanged element block with a pressure vessel and heats air, gases or liquids that are forced through it. Versions with 10 to 14 inch flanges are configured to the required power, materials and pressure.
- Type
- circulation heater with flanged element block
- Flange
- 10 to 14 inch, ANSI or plate
- Heating elements
- FIREBAR or WATROD
- Medium
- forced-flow air, gases, liquids
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The circulation heater is supplied as a ready-built assembly, with heating elements, vessel, insulation, terminal box, mounting brackets and inlet and outlet connections combined in one unit. A ready assembly reduces the time and labour needed to install electric heating.
At the core is an ANSI flanged heater connected to a pressure vessel. The medium passes along FIREBAR or WATROD heating elements, which gives a fast response and an even distribution of heat. The heaters can work in-line, where flow passes straight through, or as a side branch off the main flow. This version is designed for flanges from 10 to 14 inch and for large flows where a considerable installed power is required.
Maximum operating temperature depends on the element sheath material: 316 stainless steel up to 650 °C, Alloy 800 up to 870 °C, carbon steel up to 400 °C, and a low-temperature version up to 175 °C. The maximum watt density at the element surface is 18.6 W/cm² (120 W/in²). Heaters are made to order, with the sheath material, power, vessel size and material, pressure class, terminal boxes and controls all varied to suit.
These flange heaters are built with ANSI flanges up to 14 inch or with plate flanges, with or without thermocouples, and may include a process thermostat, thermowell, terminal box and terminal blocks as required. The rated voltage is up to 600 V AC for North America, or up to 1000 V AC (1500 V DC) for the EU, in one or three phases. The product carries a certificate of conformity to the Pressure Equipment Directive 2014/68/EU (PED).
Before start-up, the insulation resistance is checked with a megohmmeter, element overheating protection is set, orientation and mounting requirements are observed, and the power wiring is made according to the diagram. The instructions include scheduled preventive maintenance, a list of replaceable parts and a fault-finding procedure.
Technical specifications
| Type | circulation heater with flanged element block |
|---|---|
| Flange | 10 to 14 inch, ANSI or plate |
| Heating elements | FIREBAR or WATROD |
| Medium | forced-flow air, gases, liquids |
| Installation layout | in-line or side branch |
| 316 SS sheath | up to 650 °C |
| Alloy 800 sheath | up to 870 °C |
| Steel sheath | up to 400 °C |
| Low-temperature version | up to 175 °C |
| Watt density | up to 18.6 W/cm² (120 W/in²) |
| Voltage | up to 600 V AC (North America), up to 1000 V AC or 1500 V DC (EU) |
| Phases | 1 or 3 |
| Certificate | Pressure Equipment Directive 2014/68/EU (PED) |
Request a price and lead time
Flange Circulation Heaters, 10 to 14 inch Flanges, for Air, Gases and Liquids. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which media can be heated?
Forced-flow air, gases and liquids, with the heater installed in-line or as a side branch off the main flow.
What is the maximum element sheath temperature?
Up to 870 °C for Alloy 800, up to 650 °C for 316 stainless steel and up to 400 °C for carbon steel.
What voltage are the heaters made for?
Up to 600 V AC for North America and up to 1000 V AC or 1500 V DC for the EU, in one or three phases.
Similar equipment from other manufacturers