Chanscope II Portable Dewpoint Tester for Gas, Pressure up to 5000 psi

Chanscope II is a portable gas dewpoint tester supplied in three pressure models: the 1175 for 0-1000 psi, the 1200 for 0-3000 psi and the 1210 for 0-5000 psi. Each unit takes either a regular or a liquid nitrogen chiller, and an atmosphere option for standard, offshore, sour gas or oxygen service.

Type
portable dewpoint tester for gas
Model 1175
0-1000 psi
Model 1200
0-3000 psi
Model 1210
0-5000 psi

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The tester measures dewpoint directly on gas pipelines, gas treatment units and metering points where no fixed analyser is installed, or where its readings need checking with an independent instrument. The sample tap is connected to the tester, the gas passes into the measuring chamber, and the operator records the temperature at which condensate forms on the chilled surface.

Choose the model by the working pressure of the gas: the 1175 covers 0-1000 psi, the 1200 covers 0-3000 psi and the 1210 covers 0-5000 psi. The second option letter sets the chiller, where C is a regular chiller and L is a liquid nitrogen (N2) chiller, used when lower surface temperatures are needed.

The third option defines the atmosphere: N is for standard gas, R for offshore platforms and corrosive atmospheres, S for sour gas containing H2S, and X for a unit cleaned for oxygen service. The power supply is 100 to 240 VAC, 50/60 Hz, so the tester can run on mains of different standards.

Each tester is delivered with spare sealing rings, two ten foot stainless steel tubes with fittings, one for the sample gas and one for the coolant, a CD and a carrying case, so measurements can start on site without extra materials.

The manufacturer's catalogue lists CHANSCOPE-2, CHANSCOPE-S, CHANSCOPE-L, CHANSCOPE-R and CHANSCOPE-X beside the base item, corresponding to the power, chiller and atmosphere options. When ordering, state the pressure model and one code from each option group. Before measuring, check that the model matches the line pressure, the condition of the sealing rings and the tightness of the connections, and use only the S and X versions for sour gas and oxygen respectively.

Technical specifications

Typeportable dewpoint tester for gas
Model 11750-1000 psi
Model 12000-3000 psi
Model 12100-5000 psi
Chiller Cregular chiller
Chiller Lliquid nitrogen (N2)
Option Nstandard gas service
Option Roffshore platforms, corrosive atmosphere
Option Ssour gas service (H2S)
Option Xcleaned for oxygen service
Power supply (option 2)100 to 240 VAC, 50/60 Hz
Supplied withspare sealing rings, two ten foot stainless steel tubes with fittings, CD, carrying case

Part numbers

Show all part numbers (6)

MODEL CHANSCOPE II, CHANSCOPE-2, CHANSCOPE-S, CHANSCOPE-L, CHANSCOPE-R, CHANSCOPE-X

Request a price and lead time

Chanscope II Portable Dewpoint Tester for Gas, Pressure up to 5000 psi. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which Chanscope II model is suited to gas at 3000 psi?

Up to 3000 psi the 1200 model is suitable, and for pressures up to 5000 psi the 1210 model is required.

Is there a version for sour gas?

Yes, the S version is intended for sour gas containing H2S, while the R version suits corrosive offshore atmospheres.

What comes in the supply kit?

Spare sealing rings, two ten foot stainless steel tubes with fittings for the sample gas and coolant, a CD and a carrying case.