International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Chanscope II portable dew point analyser with chilled mirror to ASTM D1142

Chanscope II is a portable instrument for measuring the dew point of gas by the chilled mirror method to ASTM D1142. It determines both water dew point and hydrocarbon dew point, needs no calibration, and suits sour natural gas.

Type
Portable dew point analyser
Measurement method
Chilled mirror
Measured parameters
Water dew point and hydrocarbon dew point
Standard
ASTM D1142

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Chanscope II is a dew point analyser designed as a simple tool for staff at gas transmission and gas processing plants. It measures the dew point temperature of a gas sample by the chilled mirror method, as ASTM D1142 requires. One instrument determines both water dew point and hydrocarbon dew point, so separate instruments are not needed on site.

The chilled mirror method is direct. Condensate forms on the gradually cooled mirror surface once the dew point is reached, and the temperature is recorded at that moment. Because of this, the instrument needs no calibration, and its result serves as a reference for checking fixed electronic dew point analysers for hydrocarbons and water.

The unit is portable and sturdy enough for field use, delivering repeatable results. It can measure any gas, including sour natural gas. It is carried between sampling points on the pipeline, metering stations and process units, and measurements are taken on site without sending a sample to a laboratory.

The main field of use is natural gas, covering dehydration, liquefaction, sweetening (sulphur removal), trunk pipelines and underground storage. The instrument is also applied to steam and heat-treating gases, industrial gases, refining, and chemical and petrochemical plants.

Technical specifications

TypePortable dew point analyser
Measurement methodChilled mirror
Measured parametersWater dew point and hydrocarbon dew point
StandardASTM D1142
CalibrationNot required
Measured mediumAny gas, including sour natural gas
DesignPortable, shock-resistant
ApplicationsNatural gas, industrial gases, refining, chemicals and petrochemicals

Part numbers

Show all part numbers (1)

Chanscope II Dew Point Tester

Request a price and lead time

Chanscope II portable dew point analyser with chilled mirror to ASTM D1142. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which dew points does the Chanscope II measure?

It determines the water dew point and the hydrocarbon dew point of a gas by the chilled mirror method.

Does the instrument need periodic calibration?

No, the chilled mirror method is direct and needs no calibration.

Can it measure sour natural gas?

Yes, the instrument is suitable for measurements in any gas, including sour natural gas.