BIMETAL dual-mode remote thermometer, 3-inch dial, 0-250°F or 0-500°F, mV or ohm output

The BIMETAL gives on-site indication of process temperature and at the same time provides a mV or ohm signal proportional to temperature. 3-inch dial, 0-250°F or 0-500°F, no power supply at the measurement point.

Type
Dual-mode remote bimetal thermometer
Dial
3-inch dial, 0-250°F or 0-500°F
Sensor signal
mV or ohm signal proportional to temperature
With a transmitter
4-20mA or 1-5Vdc

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The BIMETAL Dual-Mode Remote Thermometer provides on-site indication of process temperature and simultaneously provides a mV or ohm signal proportional to temperature, for input to a transmitter, Remote Terminal Unit (RTU), controller, recorder, indicator, PLC, DCS or SCADA system. It requires no power supply at the point of measurement.

It is built from a rugged thermowell probe assembly containing an RTD or thermocouple sensor, combined with a large analogue display. Both the sensor and the display are NIST traceable. The 3-inch dial comes in 0-250°F and 0-500°F ranges, can be read accurately at numerous viewing angles and is hermetically sealed per ASME B40.3. Field calibration, with NIST traceable calibration of up to 1% of reading, is done on resettable models by placing the thermometer in a controlled liquid for at least three minutes and adjusting the hex nut on the back of the case until the pointer indicates the correct reading.

The probe has hermetically sealed, high-temperature wires and installs in 0.25-inch or 0.38-inch thermowell bores. Probe accuracy is up to 0.04% of reading, with 0.1% of reading as standard. The sensors are PT1-3, PT1-4 (100 ohm), PT10-3 and PT10-4 (1000 ohm), all with alpha = 0.00385, and J and K type ungrounded thermocouples (TC-JU, TC-KU). The stem is 0.25-inch (standard) or 0.38-inch in diameter, in stainless steel 316 (standard) or 304, and its length is specified in 1/4-inch increments, for example CL6.75.

A temperature transmitter converts the low-level mV or ohm signal to 4-20mA or 1-5Vdc, giving a noise-resistant signal for sending process data long distances. Connection styles are the standard assembly, an aluminium connection head with terminal block (LH1NS, LH2NS), and in-line conduit connection COND or COND90 with 90 degree wire entry. It is RoHS compliant.

Technical specifications

TypeDual-mode remote bimetal thermometer
Dial3-inch dial, 0-250°F or 0-500°F
Sensor signalmV or ohm signal proportional to temperature
With a transmitter4-20mA or 1-5Vdc
PowerNone required at the point of measurement
Sensor typesPT1-3, PT1-4 (100 ohm), PT10-3, PT10-4 (1000 ohm), TC-JU, TC-KU
Pt RTDalpha = 0.00385
Stem diameterD25: 0.25-inch (standard), D38: 0.38-inch
MaterialS316: stainless steel 316 (standard), S304: stainless steel 304
Stem lengthCL?, in 1/4-inch increments, for example CL6.75
Probe accuracyUp to 0.04% of reading (0.1% of reading is standard)
CalibrationNIST traceable, up to 1% of reading, field adjustable
Mounting0.25-inch or 0.38-inch thermowell bores
Connection stylesStandard, LH1NS, LH2NS, COND, COND90
SealingHermetically-sealed per ASME B40.3
RoHSYes
Order code structureBIMET / sensor type / stem diameter / material / -dial range -options -stem length [mounting]

How it compares with similar models

ParameterBIMETAL dual-mode remote thermometer, 3-inch dial, 0-250°F or 0-500°F, mV or ohm outputTDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop poweredSTZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DCTHZ3 dual input HART temperature transmitter for DIN rail, 4-20mA, 12-42DC
TypeDual-mode remote bimetal thermometerDual input smart HART temperature transmitterFunctional safety dual input smart HART temperature transmitterDual input HART temperature transmitter for DIN rail mounting
PowerNone required at the point of measurement12-42DC, 2-wire, loop powered12-42DC, 2-wire, loop powered12-42DC, 2-wire, loop powered

Request a price and lead time

BIMETAL dual-mode remote thermometer, 3-inch dial, 0-250°F or 0-500°F, mV or ohm output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the BIMETAL need a power supply?

No, none is required at the point of measurement. It shows temperature on the dial and gives a mV or ohm signal.

Which dial ranges and sensors are available?

A 3-inch dial of 0-250°F or 0-500°F. Sensors are 100 and 1000 ohm Pt RTDs (3- and 4-wire) and J and K type ungrounded thermocouples.

How is the signal converted to 4-20mA?

With a temperature transmitter, which converts the low-level mV or ohm signal to 4-20mA or 1-5Vdc.