ANSI Flange Immersion Heater, 3 to 8 inch, without Baffles, Sheath Up to 870 °C
The 3 to 8 inch flange immersion heater has no baffles and uses tubular elements mounted on an ANSI flange. It heats liquids and gases in tanks and pressure vessels, with sheaths rated up to 870 °C.
- Type
- tubular immersion heater on ANSI flange
- Flange size
- 3 to 8 inch
- Baffles
- none
- Heating elements
- WATROD (round), FIREBAR (flat)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
This heater is fitted through the flanged nozzle of a tank or vessel, with its heating elements immersed directly in the process medium. It suits liquids and gases in tanks, reservoirs and pressure vessels where a large heat output is needed. Flanges from 3 to 8 inches fit vessels with medium-sized nozzles.
The version has no baffles in the heating assembly. Where baffles are required, the maker offers a separate 3 to 8 inch modification with baffles. The elements are brazed or welded to the flange, and they are either round tubular WATROD or flat FIREBAR. The flat FIREBAR form delivers more power in a more compact bundle at a lower watt density, which helps with oil-based liquids and small tanks. The standard FIREBAR sheath is Alloy 800.
The permissible sheath temperature depends on the material. Alloy 800/840 works up to 870 °C (1600 °F), passivated 316 and 304 stainless steel up to 650 °C (1200 °F), and steel up to 400 °C (750 °F). The maximum watt density is 15.5 W/cm2 (100 W/in2), and special versions take supply voltages up to 600 V AC.
As standard the heater has a general purpose terminal box. The approval list covers UL, CSA, ATEX Ex eb, IECEx eb and PESO, and vessel design is assessed to ASME Section VIII, Div. I. A version with a thermostat is available for controlling process temperature.
Installation and maintenance follow the separate instruction for flange and circulation heaters. Flange size, sheath material, power and voltage are chosen for each vessel and medium at the selection stage.
Technical specifications
| Type | tubular immersion heater on ANSI flange |
|---|---|
| Flange size | 3 to 8 inch |
| Baffles | none |
| Heating elements | WATROD (round), FIREBAR (flat) |
| Alloy 800/840 sheath | up to 870 °C (1600 °F) |
| 316 and 304 stainless steel sheath | up to 650 °C (1200 °F) |
| Steel sheath | up to 400 °C (750 °F) |
| Watt density | up to 15.5 W/cm2 (100 W/in2) |
| Voltage | up to 600 V AC (special version) |
| Terminal box | general purpose (standard) |
| Certification | UL, CSA, ATEX Ex eb, IECEx eb, PESO |
Request a price and lead time
ANSI Flange Immersion Heater, 3 to 8 inch, without Baffles, Sheath Up to 870 °C. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How does this version differ from the one with baffles?
This version has no baffles in the heating assembly. A separate 3 to 8 inch modification with baffles is available for applications that need them.
What is the maximum sheath temperature?
Up to 870 °C for Alloy 800/840, 650 °C for stainless steel and 400 °C for steel.
Is the heater suitable for oil-based liquids?
Yes, the flat FIREBAR elements are recommended for them. They deliver more power in a compact bundle at a lower watt density.