6400T and 6400TH UV Fluorescence Sulphur Dioxide (SO2) Analysers, Ranges from 0-50 ppb
Stationary sulphur dioxide analysers that work on ultraviolet fluorescence. The minimum range is 0-50 ppb and the lower detection limit is 0.4 ppb, with zero noise below 0.2 ppb. They hold EPA equivalency for the method and carry the CE mark.
- Measuring principle
- UV fluorescence
- Measured component
- SO2
- Ranges
- 0-50 ppb to 0-20,000 ppb, dual and automatic
- Units
- ppb, ppm, µg/m3, mg/m3
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The 6400T and 6400TH measure the concentration of sulphur dioxide in a gas sample and serve ambient air quality monitoring and emissions control. The analyser holds EPA equivalent method status, carries the CE mark, and complies with EN61326-1 and EN61010-1. A single manual with addenda also covers the 6400TU, 6200T and 6200TU variants.
Measurement is based on ultraviolet fluorescence: SO2 molecules are excited by UV radiation and emit light whose intensity is proportional to the concentration. The instrument compensates for temperature and pressure. The sample flow is 650 cm3/min ±10 %, the delay time is 20 seconds, and rise and fall times are below 100 seconds to 95 %.
The user selects the range, from 0-50 ppb up to 0-20,000 ppb full scale, and dual ranges and automatic ranging are supported. Results can be shown in ppb, ppm, µg/m3 or mg/m3. The lower detection limit is 0.4 ppb, accuracy is 0.5 % of reading above 50 ppb, and linearity is 1 % of full scale. Zero and span drift stay below 0.5 ppb over 24 hours and below 1 ppb over 7 days.
Operation is from a graphical interface on a capacitive touch LCD. An internal logger stores data with averaging from 1 minute to 365 days. Calibration is performed in software, and an internal zero and span check is available as an option. The 6400TH can be fitted with a 240 V internal pump. The standard inputs and outputs include up to four analogue outputs (up to three 4-20 mA or 0-10 V, 0-5 V, 0-1 V or 0-0.1 V), Ethernet 10/100Base-T, two RS232 ports and two USB ports, plus eight opto-isolated digital outputs and six opto-isolated digital inputs. An RS485 port, eight 0-10 V analogue inputs and four alarm outputs can be added. The unit runs from 100–120 V or 220–240 V at 50/60 Hz and works between 5 °C and 40 °C.
Technical specifications
| Measuring principle | UV fluorescence |
|---|---|
| Measured component | SO2 |
| Ranges | 0-50 ppb to 0-20,000 ppb, dual and automatic |
| Units | ppb, ppm, µg/m3, mg/m3 |
| Lower detection limit | 0.4 ppb |
| Zero noise | < 0.2 ppb (RMS) |
| Zero drift | < 0.5 ppb/24 h, < 1 ppb/7 days |
| Delay time | 20 s |
| Rise and fall time | < 100 s to 95 % |
| Linearity | 1 % of full scale |
| Accuracy | 0.5 % of reading above 50 ppb |
| Sample flow | 650 cm3/min ±10 % |
| Power supply | 100–120 V, 220–240 V, 50/60 Hz |
| Analogue outputs | up to 4: 4-20 mA or 0-10 V, 0-5 V, 0-1 V, 0-0.1 V |
| Digital interfaces | Ethernet 10/100Base-T, 2 x RS232, 2 x USB, RS485 optional |
| Operating temperature | 5–40 °C |
| Dimensions (H x W x D) | 178 x 432 x 597 mm |
| Weight | 16.2 kg |
Part numbers
Show all part numbers (2)
6400T, 6400TH
Request a price and lead time
6400T and 6400TH UV Fluorescence Sulphur Dioxide (SO2) Analysers, Ranges from 0-50 ppb. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the lowest SO2 concentration the analyser measures?
The lower detection limit is 0.4 ppb and zero noise is below 0.2 ppb. The smallest range is 0-50 ppb.
Can results be displayed in mg/m3?
Yes. Units are selected from ppb, ppm, µg/m3 and mg/m3. The analyser supports dual ranges and automatic range switching.
How is the analyser connected to a data acquisition system?
Through analogue outputs of 4-20 mA or voltage, Ethernet 10/100Base-T, RS232 and USB, with RS485 optional. It has eight digital outputs and six opto-isolated inputs.