5812 Natural Gas Moisture Analyser with Quartz Crystal Sensor, 1 to 1000 ppmv

The 5812 analyser measures moisture in natural gas with a quartz crystal coated in a water-sensitive layer. It covers a calibrated range of 1 to 1000 ppmv, with trend indication above that range, and an accuracy of ±1.0 ppmv or ±5% of reading, whichever is greater.

Measured medium
natural gas
Calibrated range
1 to 1000 ppmv, trend indication above range
Sensitivity
0.02 ppmv or 0.5% of range, whichever is greater
Accuracy
±1.0 ppmv or ±5% of reading, whichever is greater

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The instrument is designed for continuous monitoring of moisture in natural gas. Measurements run without operator involvement, and the RS485 digital interface lets staff follow the analyser's status remotely at unattended sites.

The sensing element is a quartz crystal with a water-sensitive coating. Wet sample gas and the same gas after a dryer pass over it in turn, and the difference in the crystal's response between the two phases is proportional to the moisture content of the sample. This repeating cycle keeps the instrument ready to respond to any change in humidity.

Sampling is asymmetric. In each 10-minute cycle natural gas is fed to the sensor for 30 seconds, and during the rest of the cycle clean dry gas flows through the module and removes volatile contaminants. Contact between the sensor and possibly contaminated gas therefore takes about 5% of the time, which extends the service life of the element. The reference gas is conditioned by a built-in dryer and contaminant trap.

The display is a vacuum fluorescent unit with four lines of twenty characters. It shows moisture in ppmv, dew point temperature or lbs/MMscf, together with timer and instrument status. Two fully programmable 4 to 20 mA analogue outputs into a 1200 ohm load are provided, along with three independent contact closures rated at 30 V DC and 1 A resistive load for system alarm, range or calibration alert and concentration alert. The alarm signals are also available over RS485.

Inlet pressure is 1 to 10 bar (15 to 150 psig), and the operating and exhaust pressures are atmospheric. Sample flow is below 600 mL/min at standard conditions, the sample gas temperature is 0 to 100 °C and the ambient range is 4 to 40 °C at up to 90% relative humidity, non-condensing. The power supply is 85 to 265 V at 47 to 63 Hz. The unit is available for bench mounting or in a 19-inch rack, and it is rated NEC/CEC Class I, Division 2, Groups A B C D, T3C, with CE conformity to EN61010-1, EN50081-1 and EN50082-1 at installation category II and pollution degree 2.

Technical specifications

Measured mediumnatural gas
Calibrated range1 to 1000 ppmv, trend indication above range
Sensitivity0.02 ppmv or 0.5% of range, whichever is greater
Accuracy±1.0 ppmv or ±5% of reading, whichever is greater
Inlet pressure1 to 10 bar (15 to 150 psig)
Operating and exhaust pressureatmospheric
Sample flowbelow 600 mL/min at standard conditions
Sample gas temperature0 to 100 °C
Ambient temperature4 to 40 °C, up to 90% relative humidity, non-condensing
Analogue outputs2 × 4 to 20 mA, 1200 ohm load
Digital interfaceRS485, bidirectional
Alarms3 contact closures, 30 V DC, 1 A
Displayvacuum fluorescent, 4 lines × 20 characters
Power supply85 to 265 V, 47 to 63 Hz
Dimensions (W × H × D)432 × 132 × 381 mm; rack-mount version height 221 mm
Net weight8.2 kg
Hazardous area ratingNEC/CEC Class I, Division 2, Groups A B C D, T3C

Part numbers

Show all part numbers (1)

5812

Request a price and lead time

5812 Natural Gas Moisture Analyser with Quartz Crystal Sensor, 1 to 1000 ppmv. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What measurement range does the 5812 cover?

The calibrated range is 1 to 1000 ppmv, and above that range the instrument shows a trend. The display can also report readings in lbs/MMscf.

How is the sensor protected from contaminated gas?

Natural gas reaches the sensor for only 30 seconds in each 10-minute cycle, and clean dry gas purges the module for the rest of the cycle. Contact with the sample is therefore about 5% of the time.

Can the 5812 be installed in a hazardous area?

The instrument is rated NEC/CEC Class I, Division 2, Groups A B C D, T3C. Other area classifications need to be agreed in advance.