5812 Natural Gas Moisture Analyser with Quartz Crystal Sensor, 1 to 1000 ppmv
The 5812 analyser measures moisture in natural gas with a quartz crystal coated in a water-sensitive layer. It covers a calibrated range of 1 to 1000 ppmv, with trend indication above that range, and an accuracy of ±1.0 ppmv or ±5% of reading, whichever is greater.
- Measured medium
- natural gas
- Calibrated range
- 1 to 1000 ppmv, trend indication above range
- Sensitivity
- 0.02 ppmv or 0.5% of range, whichever is greater
- Accuracy
- ±1.0 ppmv or ±5% of reading, whichever is greater
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The instrument is designed for continuous monitoring of moisture in natural gas. Measurements run without operator involvement, and the RS485 digital interface lets staff follow the analyser's status remotely at unattended sites.
The sensing element is a quartz crystal with a water-sensitive coating. Wet sample gas and the same gas after a dryer pass over it in turn, and the difference in the crystal's response between the two phases is proportional to the moisture content of the sample. This repeating cycle keeps the instrument ready to respond to any change in humidity.
Sampling is asymmetric. In each 10-minute cycle natural gas is fed to the sensor for 30 seconds, and during the rest of the cycle clean dry gas flows through the module and removes volatile contaminants. Contact between the sensor and possibly contaminated gas therefore takes about 5% of the time, which extends the service life of the element. The reference gas is conditioned by a built-in dryer and contaminant trap.
The display is a vacuum fluorescent unit with four lines of twenty characters. It shows moisture in ppmv, dew point temperature or lbs/MMscf, together with timer and instrument status. Two fully programmable 4 to 20 mA analogue outputs into a 1200 ohm load are provided, along with three independent contact closures rated at 30 V DC and 1 A resistive load for system alarm, range or calibration alert and concentration alert. The alarm signals are also available over RS485.
Inlet pressure is 1 to 10 bar (15 to 150 psig), and the operating and exhaust pressures are atmospheric. Sample flow is below 600 mL/min at standard conditions, the sample gas temperature is 0 to 100 °C and the ambient range is 4 to 40 °C at up to 90% relative humidity, non-condensing. The power supply is 85 to 265 V at 47 to 63 Hz. The unit is available for bench mounting or in a 19-inch rack, and it is rated NEC/CEC Class I, Division 2, Groups A B C D, T3C, with CE conformity to EN61010-1, EN50081-1 and EN50082-1 at installation category II and pollution degree 2.
Technical specifications
| Measured medium | natural gas |
|---|---|
| Calibrated range | 1 to 1000 ppmv, trend indication above range |
| Sensitivity | 0.02 ppmv or 0.5% of range, whichever is greater |
| Accuracy | ±1.0 ppmv or ±5% of reading, whichever is greater |
| Inlet pressure | 1 to 10 bar (15 to 150 psig) |
| Operating and exhaust pressure | atmospheric |
| Sample flow | below 600 mL/min at standard conditions |
| Sample gas temperature | 0 to 100 °C |
| Ambient temperature | 4 to 40 °C, up to 90% relative humidity, non-condensing |
| Analogue outputs | 2 × 4 to 20 mA, 1200 ohm load |
| Digital interface | RS485, bidirectional |
| Alarms | 3 contact closures, 30 V DC, 1 A |
| Display | vacuum fluorescent, 4 lines × 20 characters |
| Power supply | 85 to 265 V, 47 to 63 Hz |
| Dimensions (W × H × D) | 432 × 132 × 381 mm; rack-mount version height 221 mm |
| Net weight | 8.2 kg |
| Hazardous area rating | NEC/CEC Class I, Division 2, Groups A B C D, T3C |
Part numbers
Show all part numbers (1)
5812
Request a price and lead time
5812 Natural Gas Moisture Analyser with Quartz Crystal Sensor, 1 to 1000 ppmv. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What measurement range does the 5812 cover?
The calibrated range is 1 to 1000 ppmv, and above that range the instrument shows a trend. The display can also report readings in lbs/MMscf.
How is the sensor protected from contaminated gas?
Natural gas reaches the sensor for only 30 seconds in each 10-minute cycle, and clean dry gas purges the module for the rest of the cycle. Contact with the sample is therefore about 5% of the time.
Can the 5812 be installed in a hazardous area?
The instrument is rated NEC/CEC Class I, Division 2, Groups A B C D, T3C. Other area classifications need to be agreed in advance.