4080 Hydrocarbon Purge Analyser with Flame Ionisation Detector, Ex pxb Enclosure

The 4080 measures hydrocarbon content in gases and liquids using flame ionisation. Its 4000 series measuring unit sits in a purged enclosure marked II 2 G Ex pxb IIC T* Gb for use in hazardous areas.

Measuring principle
flame ionisation detector
Ranges
0–10, 0–100, 0–1000 ppm (CH4 equivalent)
Resolution
10 ppb on the 0–1 ppm range
Accuracy
±2% of full scale at constant temperature

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The analyser measures hydrocarbons in gases and liquids on process plants. Ranges are 0–10, 0–100 and 0–1000 ppm as CH4, and lower ranges are available to order. Resolution is 10 ppb on the 0–1 ppm range, and sensitivity is 1% of full scale.

The detector is a flame ionisation type with flame protection, so no component separation is needed. The recommended fuel is a mix of 40% hydrogen and 60% nitrogen, with hydrocarbon-free instrument air supplied at 30 psi, free of oil and water. Ignition is automatic. The analyser is usable about 4 hours after switch-on, and stable readings are reached in roughly 8 hours.

Accuracy is ±2% of full scale at constant temperature, with linearity and repeatability of 1% of full scale on all ranges, zero and span noise below 0.5%, and drift of 2% of full scale per week. Response time to 90% is under 15 seconds, and sample flow is 1 litre per minute. Outputs are 0–1 V and an isolated 4–20 mA into loads up to 500 Ohm. A type C relay signals flame-out and two concentration set points, with 3 A contacts rated at 250 V AC.

Power is 115 or 220 V AC, 50/60 Hz, drawing up to 90 VA. If the flame goes out, the fuel supply is shut off, a red indicator lights and the system fault relay operates. The analyser module sits in a steel 19-inch rack enclosure measuring 48.3 x 22.2 x 39.4 cm, and an optional built-in manifold automates the span check for samples below 60° C. For maintenance, the manufacturer recommends keeping spares such as the F-1404 filter, T-1088 FID regulator, CP-1806 fibre-optic assembly, R-2243 back-pressure regulator, B-60091 RTD cable, B-549 soda lime, D-486 dryer and W-88 glass wool.

The purged enclosure is cold-rolled or 316 stainless steel with an Ex e certified viewing window. It is purged with air in continuous dilution mode or with nitrogen in leakage compensation mode, at a minimum flow of 140 SLPM for at least 13 minutes. Overpressure inside the enclosure runs from 1.2 to 13 mbar, and supply pressure from 3 to 5 bar. The temperature class is T4, or T3 with suitable external equipment, and the unit complies with EN 60079-0:2012+A11:2014 and EN 60079-2:2014 under Directive 94/9/EC at ambient temperatures from -20 to +40 °C. The certificate covers the 4080/4020 Q, 4080/4030, 4080/4040, 4080/4060, 4020B, 4030B, 4040B and 4060B versions.

Technical specifications

Measuring principleflame ionisation detector
Ranges0–10, 0–100, 0–1000 ppm (CH4 equivalent)
Resolution10 ppb on the 0–1 ppm range
Accuracy±2% of full scale at constant temperature
Linearity / repeatability1% of full scale
Zero and span drift2% of full scale per week
Response time90% in under 15 s
Sample flow1 l/min
Outputs0–1 V, isolated 4–20 mA, up to 500 Ohm
Relaytype C, 3 A, 250 V AC, 50/60 Hz
Power115 or 220 V AC, 50/60 Hz, up to 90 VA
Operating temperature40–110° F
Fuel40% H2 / 60% N2
MarkingII 2 G Ex pxb IIC T* Gb, -20°C < Ta < +40°C
Purgingfrom 140 SLPM N2 or air, from 13 min
Enclosure overpressure1.2–13 mbar
Purge supply pressure3–5 bar
Enclosure materialcold-rolled steel or 316 stainless steel
StandardsEN 60079-0:2012+A11:2014, EN 60079-2:2014

Part numbers

Show all part numbers (8)

4080/4020 Q, 4080/4030, 4080/4040, 4080/4060, 4020B, 4030B, 4040B, 4060B

Request a price and lead time

4080 Hydrocarbon Purge Analyser with Flame Ionisation Detector, Ex pxb Enclosure. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the 4080 analyser be installed in a hazardous area?

Yes, the purged enclosure is marked II 2 G Ex pxb IIC T* Gb for ambient temperatures from -20 to +40 °C. The temperature class is T4, and T3 is permitted with suitable external equipment.

Which gases does the detector need?

The recommended fuel is a mix of 40% hydrogen and 60% nitrogen, plus hydrocarbon-free instrument air at 30 psi. For purging the enclosure, nitrogen or air is needed at a flow of at least 140 SLPM.

What signals does the analyser send to the control system?

An analogue 0–1 V output and an isolated 4–20 mA output into loads up to 500 Ohm. There is a type C relay for flame-out and two concentration set points.