
ANSI 3 to 8 inch flange immersion heaters with baffles, up to 600 V AC
Flanged immersion heaters on ANSI flanges from 3 to 8 inches heat liquids and gases in vessels and pressure vessels. The version with 316 stainless steel baffles directs flow in forced circulation systems. The standard rating reaches one megawatt at up to 600 V AC.
- Type
- flanged immersion heater with baffles
- Flange
- ANSI, 3 to 8 inches
- Heating elements
- WATROD or FIREBAR
- Output
- up to one megawatt (standard); up to three megawatts
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
These heaters go where a high heat output is needed in a liquid or gas inside process tanks, reservoirs and pressure vessels. The heater is mounted through a flanged nozzle, so it can be installed and serviced without dismantling the vessel.
The heater consists of WATROD or FIREBAR tubular elements brazed or welded to the flange, and standard units have a general purpose terminal box. FIREBAR elements have a flat profile, so a larger output fits into a smaller bundle at a lower surface watt density. This form suits petroleum-based liquids and small vessels that need a large heat load. Baffles of 316 stainless steel guide the flow along the elements in forced circulation systems.
Standard output reaches one megawatt, and up to three megawatts can be supplied to order. The supply voltage goes up to 600 V AC, and surface watt density up to 100 W/in2 (15.5 W/cm2). Sheath materials for WATROD elements are 316 stainless steel, steel and Alloy 800, while FIREBAR uses Alloy 800. Titanium and Alloy 400 and 600 sheaths are available on request.
The maximum sheath temperature depends on the material: 400 °C for steel, 650 °C for stainless steel and 870 °C for Alloy 800. The choice of material depends on the medium, the temperature and the surface watt density. For hazardous areas the heaters are available to ATEX II 2 G Ex d IIB+H2 T1-6 Gb, IECEx d IIC T1-6 Gb, ATEX II 2 G Ex e IIC T1-6 Gb and IECEx e IIC T1-6 Gb, and to Class 1, Divisions 1 and 2, Groups B, C and D, and PESO Zone 1 Group IIC. They carry UL and CSA component recognition as well as IECEx, ATEX and TR-CU EAC certificates, and vessels can be built to ASME Section VIII, Div. I.
Technical specifications
| Type | flanged immersion heater with baffles |
|---|---|
| Flange | ANSI, 3 to 8 inches |
| Heating elements | WATROD or FIREBAR |
| Output | up to one megawatt (standard); up to three megawatts |
| Voltage | up to 600 V AC |
| Surface watt density | up to 100 W/in2 (15.5 W/cm2) |
| Sheath, standard | WATROD: 316 SS, steel, Alloy 800; FIREBAR: Alloy 800 |
| Sheath, on request | titanium, Alloy 400 and 600 |
| Max. temperature, steel | 400 °C |
| Max. temperature, stainless steel | 650 °C |
| Max. temperature, Alloy 800 | 870 °C |
| Baffles | 316 stainless steel, for forced circulation |
| Hazardous area approvals | ATEX II 2 G Ex d IIB+H2 / Ex e IIC; IECEx d IIC / e IIC; Class 1, Div. 1 & 2, Groups B, C & D; PESO Zone 1 |
| Certifications | UL and CSA (components), IECEx, ATEX, TR-CU EAC |
Request a price and lead time
ANSI 3 to 8 inch flange immersion heaters with baffles, up to 600 V AC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What are the baffles for?
The 316 stainless steel baffles guide the flow along the heating elements in forced circulation systems.
What is the maximum sheath temperature?
400 °C for steel, 650 °C for stainless steel and 870 °C for Alloy 800.
Can the heater be used in a hazardous area?
Yes. Versions are available to ATEX and IECEx Ex d and Ex e, and for Class 1, Divisions 1 and 2.
Similar equipment from other manufacturers






