2000XTC Thermal Conductivity Transmitter for H2, He, N2, Ar and CO2, 4 to 20 mA Output

The 2000XTC determines the concentration of H2, He, N2, Ar, CO2 and other gases in binary and multi-component mixtures from their thermal conductivity. The intrinsically safe transmitter sits in a NEMA 4X (IP66) enclosure for outdoor installation in hazardous areas.

Measuring principle
thermal conductivity
Sensor
silicon micromachined solid-state thermal conductivity sensor
Measured gases
H2, He, N2, Ar, CO2 and others
Power supply
24 V DC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The transmitter is used wherever gas composition can be estimated from its thermal conductivity. Typical tasks include checking hydrogen purity in the purge gas of turbogenerators at power stations, analysing H2 in circulating H2/hydrocarbon streams, and monitoring tail gas treatment units at petrochemical plants. It is also used to check gas purity in air separation units, to verify cylinders of welding, breathing and calibration mixtures, and to monitor protective atmospheres in annealing furnaces. Further uses include the purity of H2 in O2 during electrolysis, methane purity at the inlet of fuel cell reformers, CH4 concentration in natural gas (80 to 100% CH4), binary mixtures such as Ar or N2 in air, and CO2 for safety purposes.

The sensing element is a silicon micromachined solid-state thermal conductivity sensor. The measuring cell is a nickel-plated brass block with stainless steel tubes. No reference gas is needed. Gas connections are 1/4 inch compression fittings, and a sample flow of 0.4 to 2.0 SCFH is recommended.

The system consists of a measuring unit and an interface unit. The measuring unit is wall mounted in a NEMA 4X (IP66) enclosure. The interface unit mounts on a DIN rail and is placed in a safe area, in an enclosure rated IP20 or higher or in an enclosure with a rated type of explosion protection. The cable between the units can be up to 100 feet long. Power is 24 V DC, with consumption up to 11 W. The 4 to 20 mA output is linear with concentration, with a maximum load resistance of 700 ohms.

Accuracy is ±2% of scale at constant temperature and ±5% of scale across 0 to 50 °C. Zero and span drift is typically ±1% over 48 hours. The 10 to 90% response time is under 20 seconds, depending on the application and flow rate. The operating temperature of the system is 0 to 50 °C.

For explosion protection, the transmitter is intrinsically safe for Class I, Division 1, Groups A, B, C and D. Under ATEX it is marked II (2)/2 G Ex [ib] ib IIC T3 Gb, with certificate ISSeP08ATEX018, and conforms to EN 60079-0 and EN 60079-11. The unit is also used in semiconductor manufacturing, control of petrochemical processes, gas blending and quality control.

Technical specifications

Measuring principlethermal conductivity
Sensorsilicon micromachined solid-state thermal conductivity sensor
Measured gasesH2, He, N2, Ar, CO2 and others
Power supply24 V DC
Power consumptionup to 11 W
Output signal4 to 20 mA, linear
Load resistanceup to 700 ohms
Accuracy±2% of scale at constant temperature; ±5% of scale at 0 to 50 °C
Zero and span drift±1% over 48 hours
Response time 10 to 90%under 20 s
Operating temperature0 to 50 °C
Sample flow0.4 to 2.0 SCFH
Gas connection1/4 inch compression fittings
Cell materialnickel-plated brass, stainless steel tubes
Measuring unit enclosureNEMA 4X (IP66), wall mounted
Interface unitDIN rail mounted
Explosion protectionClass I, Div 1, Groups A, B, C, D; II (2)/2 G Ex [ib] ib IIC T3 Gb

Part numbers

Show all part numbers (1)

2000XTC

Request a price and lead time

2000XTC Thermal Conductivity Transmitter for H2, He, N2, Ar and CO2, 4 to 20 mA Output. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the 2000XTC need a reference gas?

No, the transmitter works without a reference gas. The sample is fed through 1/4 inch compression fittings at a flow of 0.4 to 2.0 SCFH.

What is the maximum distance between the measuring unit and the interface unit?

The cable between the units can be up to 100 feet long, with the interface unit placed in a safe area.

What accuracy does the instrument give?

±2% of scale at constant temperature and ±5% of scale at 0 to 50 °C, with zero and span drift typically ±1% over 48 hours.