2000RS Thermal Conductivity Gas Analyser for Binary Gas Mixtures, up to 3 Ranges

The 2000RS measures the content of one component in a binary gas mixture from its thermal conductivity. Its detector has four filaments, the analyser supports up to three measuring ranges, and both repeatability and linearity reach 1 % F.S. Up to four units fit a 19-inch, 3U panel.

Measuring principle
thermal conductivity, four-filament detector (Wheatstone bridge)
Ranges
up to 3 (application-specific)
Repeatability
1 % F.S. at constant temperature
Linearity
1 % F.S. at constant temperature

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The analyser is intended for continuous analysis of binary gas streams based on argon, helium, hydrogen, nitrogen and other gases. The maker lists more than 100 gas combinations and up to 11 measured gases. Linearisation is carried out automatically from a built-in curve or from values set by the customer. The range is selected automatically or fixed by the operator, and up to three ranges can be configured for a given application.

The measuring cell is heated to a constant temperature. Four detector filaments are connected in a Wheatstone bridge: two are bathed in a reference gas of known thermal conductivity, either sealed or flowing, and two are in contact with the sample. While the thermal conductivity of sample and reference is equal, the bridge stays balanced and the voltage difference is zero. When the sample composition changes, the temperature and resistance of the measuring filaments rise or fall, and a voltage proportional to the volume concentration of the measured gas appears across the bridge.

The front panel measures about 10.9 x 12.9 cm, so up to four units fit a 19-inch, 3U panel. The main parameters are shown on a 3.5-inch colour touchscreen LCD with a graphical interface. All gas connections and input and output terminals sit on the rear panel, and the case measures 10.9 x 12.9 x 44.7 cm and weighs 4.2 kg. For the control system there is an isolated 4-20 mA or 0-1 V DC analogue output, the same range identification signal, and four normally open Form-A contacts that indicate the range number. Form-C relays provide one system fault alarm and two concentration alarms, and RS-232 and Profibus-DP are the digital interfaces.

Flow through the sample and reference paths can be set between 50 and 200 ccm. At 200 ccm the T90 response time stays under 15 seconds, and repeatability and linearity both reach 1 % F.S. at constant temperature. The unit runs from 24 VDC, or from 100 to 240 VAC at 50/60 Hz with an adapter, drawing 40 W, and its operating range is 0 to 50 °C. It carries CE marking for radio and electromagnetic interference and the Low Voltage Directive, and it meets UKCA requirements. The 2000RS-C version includes the Auto Cal function for automatic calibration.

Technical specifications

Measuring principlethermal conductivity, four-filament detector (Wheatstone bridge)
Rangesup to 3 (application-specific)
Repeatability1 % F.S. at constant temperature
Linearity1 % F.S. at constant temperature
Response timeT90 below 15 s at 200 ccm
Operating temperature0 to 50 °C
Sample flow50–200 ccm
Reference gas flow50–200 ccm
Display3.5-inch colour touchscreen LCD
Analogue outputs4-20 mA (isolated) or 0-1 V DC
Alarms1 system fault, 2 concentration; Form-C relays
Range identification4-20 mA or 0-1 V DC; 4 Form-A contacts
InterfacesRS-232, Profibus-DP
Power24 VDC (optional 100–240 VAC, 50/60 Hz with adapter)
Consumption40 W
Dimensions10.9 x 12.9 x 44.7 cm
Weight4.2 kg
ComplianceCE, UKCA

Part numbers

Show all part numbers (2)

2000RS, 2000RS-C

Request a price and lead time

2000RS Thermal Conductivity Gas Analyser for Binary Gas Mixtures, up to 3 Ranges. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which gases can the 2000RS measure?

Binary mixtures based on argon, helium, hydrogen, nitrogen and other gases. The maker lists more than 100 combinations and up to 11 measured gases.

What is the difference in the 2000RS-C?

The 2000RS-C includes the Auto Cal function for automatic calibration.

How is the analyser connected to a process control system?

Through the isolated 4-20 mA or 0-1 V DC output, Form-C relay contacts for fault and concentration alarms, and the RS-232 and Profibus-DP interfaces.