International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Veri*Lite (ESP) VLS Polymer Suspension Insulator for 15–69 kV Lines, SML 70 kN

Veri*Lite (ESP) VLS suspension insulators take the place of disc strings on overhead lines rated 15–69 kV, and a single unit replaces between two and five discs. The 0.625 in (16 mm) core and the sheds are moulded in ESP polymer, with a specified mechanical load of 15,000 lb (70 kN) and between 4 and 12 sheds.

Application
suspension insulator
Material of core and sheds
ESP polymer
Core diameter
0.625 in (16 mm)
Number of sheds
4–12

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Every unit in the range shares the same mechanical ratings: the SML is 15,000 lb (70 kN), and the RTL is half that, at 7,500 lb (35 kN). Each insulator passes a factory proof test at 10,000 lb (44.5 kN), held for 10 seconds. The SML is the tensile load the unit withstands for 90 seconds without failure, a figure comparable with the M&E class of porcelain insulators.

The core measures 0.625 in (16 mm) across, with the sheds moulded over it from ESP polymer, and all sheds share one uniform profile. The standard end fitting is a ball and socket to ANSI 52-3, with a steel ball and malleable iron socket, while the alternative uses a steel clevis eye and tongue. Cotter pins are stainless steel in both cases.

The range comprises 4, 6, 8, 10 and 12 sheds. Section length grows from 11.5 in (292 mm) to 34.5 in (876 mm), while the shed diameter is 5.9 in (150 mm) for every size, and net weight runs from 4 to 7 lb. Types VLS-2 to VLS-6 match typical line voltages of 15/25, 35/46, 46/69 and 69 kV. Codes 4050021301 to 4050061301 are ball and socket versions, and codes 4050021400 to 4050061400 are clevis versions rated for 25, 46 and 69 kV.

Selection depends on the line voltage and on the hardware already fitted to the pole and conductor. Shed count and section length come from the VLS type table, while the ball and socket to ANSI 52-3 or the clevis eye and tongue are matched to existing line hardware. The units are manufactured to ANSI and CSA requirements.

Technical specifications

Applicationsuspension insulator
Material of core and shedsESP polymer
Core diameter0.625 in (16 mm)
Number of sheds4–12
Shed profileuniform
Section length11.5–34.5 in (292–876 mm)
Shed diameter5.9 in (150 mm)
Net weight4–7 lbs
SML15000 lbs (70 kN)
RTL7500 lbs (35 kN)
Proof test in tension10000 lbs (44.5 kN), 10 s
End fittingball and socket ANSI 52-3; clevis eye and tongue
Fitting materialsteel / malleable iron
Cotter pinstainless steel
Typical line voltage15/25, 35/46, 46/69, 69 kV
TypesVLS-2 to VLS-6
StandardsANSI, CSA

Part numbers

Show all part numbers (10)

4050021301, 4050031301, 4050041301, 4050051301, 4050061301, 4050021400, 4050031400, 4050041400, 4050051400, 4050061400

Request a price and lead time

Veri*Lite (ESP) VLS Polymer Suspension Insulator for 15–69 kV Lines, SML 70 kN. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which VLS type should be used for a 35 kV line?

The VLS-3 is designed for a typical 35/46 kV line. It has six sheds and a 17.25 in (438 mm) section length, and code 4050031301 carries ball and socket fittings.

How do codes 4050021301 and 4050021400 differ?

Codes 4050021301 to 4050061301 carry ANSI 52-3 ball and socket fittings, while codes 4050021400 to 4050061400 have steel clevis eye and tongue fittings.

How many disc insulators does one unit replace?

Depending on the type, one unit replaces between two and five disc insulators of the 10 x 5-3/4 in distribution strain type.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides