International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SubCon — busbar fittings and clamps for 230–765 kV substations

SubCon busbar fittings and clamps for open-air switchgear of 230–765 kV substations with rigid and flexible busbars. The fittings are supplied as a complete set according to the project, including anti-corona shields for equipment terminals.

Range
hardware clamps, connectors (straight, T-shaped, 45°/90° angle, parallel), expansion joints, busbar supports, earthing and stud clamps, A-shaped connectors
Design
bolted, compression, welded
Voltage
230 kV, 500 kV, 765 kV; experience with 800 and 1100 kV, EHV AC and DC substations
Shielding
corona rings, balls, busbar caps; shields for bushings, CT/VT, transformers

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The range includes hardware clamps, straight, T-shaped, 45°/90° angle and parallel connectors, expansion joints, busbar supports, earthing and stud clamps, and A-shaped connectors. Connections are bolted, compression or welded. Fittings are produced for 230, 500 and 765 kV, and there is experience with 800 and 1100 kV projects and at EHV AC and DC substations. For shielding, the range uses corona rings, balls and busbar caps, as well as shields for bushings, CT/VT and transformers.

Technical specifications

Rangehardware clamps, connectors (straight, T-shaped, 45°/90° angle, parallel), expansion joints, busbar supports, earthing and stud clamps, A-shaped connectors
Designbolted, compression, welded
Voltage230 kV, 500 kV, 765 kV; experience with 800 and 1100 kV, EHV AC and DC substations
Shieldingcorona rings, balls, busbar caps; shields for bushings, CT/VT, transformers

Request a price and lead time

SubCon — busbar fittings and clamps for 230–765 kV substations. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)7616 99 90 00
HS, 6 digits7616 99
CN (EU)7616 99 90
HTSUS (USA)7616 99 51 90
China customs tariff7616 99 10 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which voltage classes are SubCon fittings made for?

For 230, 500 and 765 kV. There is experience with 800 and 1100 kV and at EHV AC and DC substations.

What connection designs are available?

Bolted, compression and welded. Angle connectors are made at 45° and 90°.

Are anti-corona shields supplied?

Yes, corona rings, balls and busbar caps, as well as shields for bushings, CT/VT and transformers. The fittings are supplied as a set according to the open-air switchgear project.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides