
SubCon — busbar fittings and clamps for 230–765 kV substations
SubCon busbar fittings and clamps for open-air switchgear of 230–765 kV substations with rigid and flexible busbars. The fittings are supplied as a complete set according to the project, including anti-corona shields for equipment terminals.
- Range
- hardware clamps, connectors (straight, T-shaped, 45°/90° angle, parallel), expansion joints, busbar supports, earthing and stud clamps, A-shaped connectors
- Design
- bolted, compression, welded
- Voltage
- 230 kV, 500 kV, 765 kV; experience with 800 and 1100 kV, EHV AC and DC substations
- Shielding
- corona rings, balls, busbar caps; shields for bushings, CT/VT, transformers
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The range includes hardware clamps, straight, T-shaped, 45°/90° angle and parallel connectors, expansion joints, busbar supports, earthing and stud clamps, and A-shaped connectors. Connections are bolted, compression or welded. Fittings are produced for 230, 500 and 765 kV, and there is experience with 800 and 1100 kV projects and at EHV AC and DC substations. For shielding, the range uses corona rings, balls and busbar caps, as well as shields for bushings, CT/VT and transformers.
Technical specifications
| Range | hardware clamps, connectors (straight, T-shaped, 45°/90° angle, parallel), expansion joints, busbar supports, earthing and stud clamps, A-shaped connectors |
|---|---|
| Design | bolted, compression, welded |
| Voltage | 230 kV, 500 kV, 765 kV; experience with 800 and 1100 kV, EHV AC and DC substations |
| Shielding | corona rings, balls, busbar caps; shields for bushings, CT/VT, transformers |
Request a price and lead time
SubCon — busbar fittings and clamps for 230–765 kV substations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 7616 99 90 00 |
|---|---|
| HS, 6 digits | 7616 99 |
| CN (EU) | 7616 99 90 |
| HTSUS (USA) | 7616 99 51 90 |
| China customs tariff | 7616 99 10 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Which voltage classes are SubCon fittings made for?
For 230, 500 and 765 kV. There is experience with 800 and 1100 kV and at EHV AC and DC substations.
What connection designs are available?
Bolted, compression and welded. Angle connectors are made at 45° and 90°.
Are anti-corona shields supplied?
Yes, corona rings, balls and busbar caps, as well as shields for bushings, CT/VT and transformers. The fittings are supplied as a set according to the open-air switchgear project.
Similar equipment from other manufacturers





