International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Spacer dampers and aeolian vibration dampers for HV overhead lines

The company makes spacer dampers, including 8-conductor types, and vibration dampers for bundled phases of transmission overhead lines of 220–400 kV and above. The products protect conductors from aeolian vibration and galloping and are used, among others, on 380–400 kV TenneT lines (Netherlands).

Phase bundle
up to 8 conductors
Purpose
protection against aeolian vibration and galloping of conductors
Voltage class
overhead lines 220–400 kV and above
Example
triple spacer dampers for 380 kV TenneT lines; 400 kV Wintrack

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A spacer holds the conductors of a bundled phase at a set distance and keeps them from touching and abrading in wind and under short-circuit currents. The damping elements of the spacer suppress oscillations of the subconductors, while separate vibration dampers are placed near the clamps, where fatigue damage to the conductor is most likely. The designs cover bundles of up to 8 conductors. Triple spacer dampers were supplied for 380 kV TenneT lines, as well as products for 400 kV Wintrack lines.

Technical specifications

Phase bundleup to 8 conductors
Purposeprotection against aeolian vibration and galloping of conductors
Voltage classoverhead lines 220–400 kV and above
Exampletriple spacer dampers for 380 kV TenneT lines; 400 kV Wintrack

Request a price and lead time

Spacer dampers and aeolian vibration dampers for HV overhead lines. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)7616 99 90 00
HS, 6 digits7616 99
CN (EU)7616 99 90
HTSUS (USA)7616 99 51 90
China customs tariff7616 99 10 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How many conductors per phase do the spacers cover?

Up to 8 conductors in a bundled phase.

What voltage class are the spacer dampers used for?

For overhead lines of 220–400 kV and above.

Where have these products already been used?

On 380–400 kV TenneT lines in the Netherlands, including triple spacer dampers for 380 kV lines and products for 400 kV Wintrack.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides