Quadri*Sil Pivoting Horizontal V Assembly, Braced Line Post, Silicone, 138–230 kV

The Quadri*Sil pivoting horizontal V assembly attaches to the pole through a pivot fitting and holds the conductor of a 138, 161 or 230 kV line. Minimum ultimate longitudinal strength is 7500 lb, while the vertical figure lies between 10070 and 10310 lb.

Type
pivoting horizontal V assembly
Insulation material
silicone
Fitting material
galvanised steel
Live line end fitting
two hole blade

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Compared with a rigid V assembly, this version is mounted to the pole through a pivot fitting, and its angle is zero. Like the other members of the family it pairs a suspension insulator with a post insulator in one unit, which raises transverse strength and vertical loading over a single post insulator while keeping the right of way narrow. The range contains six variants: BLP041P00000 and BLP048P00000 for 115/138 kV, BLP053P00000 and BLP055P00000 for 161 kV, and BLP072P00000 and BLP080P00000 for 230 kV.

The insulator is silicone with uniform sheds 5.06 in across on a 2.5 in rod. End fittings are galvanised steel, with a two hole blade on the conductor side.

BLP041P00000 stands 50.0 in tall, measures 10 in in both width and length, and sits 18 in from the pole. Its suspension insulator is 52.2 in long, the effective length is 53.1 in and the brace section is 59.2 in. Creepage distance reaches 99 in, and the dry arc distance is 38.1 in. Critical impulse flashover is 575 kV and 625 kV, the lightning withstand is 515 kV and 560 kV, and the 60 Hz withstand is 370 kV dry and 265 kV wet.

BLP048P00000 is longer, at 56.0 in high and 20 in from the pole, with a 58.7 in suspension insulator, a 57.9 in effective length and a 65.7 in brace. Creepage distance rises to 126 in and the dry arc distance to 43 in. Critical impulse flashover is 650 kV and 720 kV, the lightning withstand is 585 kV and 680 kV, and the 60 Hz withstand is 460 kV dry and 305 kV wet, with wet flashover at 410 kV.

Tensile strength and minimum ultimate longitudinal strength are both 7500 lb for every version. Vertical strength is 10140 lb for BLP041, 10270 lb for BLP048, 10070 lb for BLP053, 10310 lb for BLP055, and 10150 lb for BLP072 and BLP080. The assemblies are built to ANSI standards.

Technical specifications

Typepivoting horizontal V assembly
Insulation materialsilicone
Fitting materialgalvanised steel
Live line end fittingtwo hole blade
Pole end mountingpivot
Shed profileuniform
Shed diameter5.06 in
Rod diameter2.5 in
Angle0
Height50.0 / 56.0 in
Distance from pole18 / 20 in
Creepage distance99 / 126 in
Dry arc distance38.1 / 43 in
60 Hz withstand, dry370 / 460 kV
Tensile strength7500 lb
Minimum ultimate L7500 lb
Minimum ultimate V10070–10310 lb
Voltage class115/138, 161, 230 kV
StandardANSI

Part numbers

Show all part numbers (6)

BLP041P00000, BLP048P00000, BLP053P00000, BLP055P00000, BLP072P00000, BLP080P00000

Request a price and lead time

Quadri*Sil Pivoting Horizontal V Assembly, Braced Line Post, Silicone, 138–230 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the pivoting V assembly differ from the standard one?

It mounts to the pole through a pivot fitting and has an angle of zero. The standard horizontal V assembly has an aluminium Flat or Gain base instead.

Which codes suit a 161 kV line?

For 161 kV, use BLP053P00000, which has a vertical strength of 10070 lb, or BLP055P00000, which has 10310 lb.

What longitudinal strength does the assembly withstand?

The minimum ultimate longitudinal strength is 7500 lb for all six versions, and the tensile strength is also 7500 lb.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides