International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Conductor connectors and helical fittings: CRS automatic splices, ConductRlink/ConductRvise, bolted clamps, armor rods, ties, tension helical clamps

Automatic, bolted and tension connectors and helical fittings for aluminium, copper and steel overhead conductors. The CRS automatic splice belongs to the full tension class A under ANSI C119.4 and holds at least 95% of the conductor's breaking strength. The fittings are used for splicing, anchoring, taps and protecting the conductor at attachment points.

CRS
automatic splice for aluminium conductors #4–795; pop-up indicator of full insertion; full tension class A under ANSI C119.4
ConductRlink / ConductRvise (7650)
automatic splices and tension clamps for ACSR
Copper
splices, tension and transition connectors for solid and stranded copper and bimetal
Steel
Strandlink / Strandvise for guy strands (EHS, aluminium-clad and general purpose); Wirevise / Wirelink for steel wire

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The range covers all the main operations with the conductor on overhead lines. Fittings are produced for conductors of aluminium and its alloys, ACSR, copper and steel, and also for guy strands. For each cross-section there are several ranges and lengths, and to select an alternative to products of other brands the manufacturer offers a cross-reference table.

The CRS (Corrosion Resistant Splice) automatic splice is intended for aluminium-based conductors from #4 to #795. A pop-up tongue on each side shows that the conductor has reached the end, and this can be seen and felt by touch. The CRS uses a synthetic corrosion inhibitor with a wide temperature range, a stainless steel spring and an aluminium guide cup, and ventilation holes let out moisture and cool the joint. This design is intended for coastal, industrial, urban and rural conditions. The standard 7652AP splice and the corrosion-resistant 7652APCRS both hold at least 95% of the conductor's breaking strength, and both have been verified by millions of pieces in service. The 7650 series ConductRlink (automatic splice) and ConductRvise (automatic tension clamp) are intended for ACSR conductors.

For copper conductors, splices, tension and transition connectors approved for solid and stranded copper and bimetal are produced. Steel guy strands are joined with Strandlink and Strandvise products of two classes: Universal for extra high strength EHS strands and aluminium-clad strands, and All Grade for high-strength strands and for general and 'utility' class strands. Wirevise and Wirelink are intended for steel wire. Bolted connectors are installed at taps and joints with minimal tension. These are hot line clamps and stirrups, aluminium and bronze vise-type clamps, parallel, wedge and T-shaped clamps, as well as transformer tank earthing clamps.

Helical fittings include armour rods and protectors made of high-strength aluminium alloy. They increase the stiffness of the conductor at attachment points and reduce wear, bending and clamping stresses. Sets are selected for conductors from #6 to 1780 kcmil, rod lengths are 40–100″, the sets have colour coding, and the rod ends are made with a bevel, a ball or a beak tip for NVN. The programme also includes Top Tie and Side Tie ties, ARMORLOCK ties, coil ties, helical suspension clamps and tension helical clamps for distribution lines, service drops and guy strands.

Technical specifications

CRSautomatic splice for aluminium conductors #4–795; pop-up indicator of full insertion; full tension class A under ANSI C119.4
ConductRlink / ConductRvise (7650)automatic splices and tension clamps for ACSR
Coppersplices, tension and transition connectors for solid and stranded copper and bimetal
SteelStrandlink / Strandvise for guy strands (EHS, aluminium-clad and general purpose); Wirevise / Wirelink for steel wire
Boltedhot line clamps, aluminium and bronze vise-type clamps, parallel and wedge clamps
Helical fittingsarmour rods and protectors (high-strength aluminium alloy; conductors #6–1780 kcmil), Top/Side Tie, ARMORLOCK, tension helical, service drop, guy and coil ties

Request a price and lead time

Conductor connectors and helical fittings: CRS automatic splices, ConductRlink/ConductRvise, bolted clamps, armor rods, ties, tension helical clamps. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which conductor sizes is the CRS splice suitable for?

The CRS is designed for aluminium-based conductors from #4 to #795. The joint belongs to the full tension class A under ANSI C119.4 and holds at least 95% of the conductor's breaking strength.

What is used to joint ACSR conductors?

The 7650 series is designed for ACSR, in which the ConductRlink performs automatic splicing and the ConductRvise works as an automatic tension clamp.

Which conductors are armour rod sets designed for?

The armour rod sets are selected for conductors from #6 to 1780 kcmil, with rod lengths from 40 to 100″. The sets have colour coding, and the rod ends are beveled, ball-shaped or beak-shaped for NVN.