International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Long Rod long rod porcelain insulators for overhead lines

PPC Long Rod are long rod suspension insulators for high and extra-high voltage AC and DC overhead lines. The mechanical failing load reaches 530 kN and element length is up to 1860 mm. The puncture-proof design rules out the typical mechanical failures of cap-and-pin and polymer insulators.

Mechanical failing load
up to 530 kN
Element length
up to 1860 mm
Rod diameter
up to 125 mm
Shed diameter
up to 265 mm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The insulator is made of C-130 alumina porcelain to IEC 60672. Rod diameter is up to 125 mm, shed diameter up to 265 mm and creepage distance up to 55 mm/kV. End fittings are made to IEC, DIN or ÖNORM and are cemented in with lead-antimony alloy. For polluted areas the insulator can be ordered with an RTV silicone coating.

Technical specifications

Mechanical failing loadup to 530 kN
Element lengthup to 1860 mm
Rod diameterup to 125 mm
Shed diameterup to 265 mm
Creepage distanceup to 55 mm/kV
MaterialC-130 alumina porcelain (IEC 60672)
End fittingsper IEC, DIN, ÖNORM; cemented in with lead-antimony alloy
OptionRTV silicone coating

Request a price and lead time

Long Rod long rod porcelain insulators for overhead lines. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8546 20 00 10
HS, 6 digits8546 20
CN (EU)8546 20 00
HTSUS (USA)8546 20 00 30
China customs tariff8546 20 90 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What is the mechanical failing load of Long Rod insulators?

The failing load is up to 530 kN with a rod diameter of up to 125 mm.

How does a long rod insulator differ from a cap-and-pin insulator?

The porcelain rod is puncture-proof, so the typical mechanical failures of cap-and-pin and polymer insulators are ruled out.

Can the insulators be used in polluted areas?

Yes, the creepage distance is up to 55 mm/kV, and an RTV silicone coating is available as an option.

Similar equipment from other manufacturers