Glass insulators for 5–69 kV distribution networks (pin-type VHT20T, VHT22T, RP5 and cap-and-pin)

Toughened glass insulators for 5–69 kV distribution networks: pin-type VHT20T, VHT22T, RP5 and cap-and-pin. Pin-type insulators are fitted to bare conductors with a cross-section of 22–228 mm² and to insulated conductors, cap-and-pin insulators are assembled into suspension and tension strings of MV overhead lines.

Voltage
5–69 kV
Pin-type
VHT20T, VHT22T, RP5 — for bare (22–228 mm²) and insulated conductors
Cap-and-pin
40 kN (IEC 11), 70–120 kN (IEC 16), standard and fog profile
Material
toughened glass

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Pin-type insulators have a rigid design. Cap-and-pin insulators are made for 40 kN (IEC 11) and for 70–120 kN (IEC 16), in standard and fog profiles. The range covers overhead networks from LV to MV, as well as railway catenary. For LV the company also makes annealed glass insulators A22 and VHC64.

Technical specifications

Voltage5–69 kV
Pin-typeVHT20T, VHT22T, RP5 — for bare (22–228 mm²) and insulated conductors
Cap-and-pin40 kN (IEC 11), 70–120 kN (IEC 16), standard and fog profile
Materialtoughened glass

Request a price and lead time

Glass insulators for 5–69 kV distribution networks (pin-type VHT20T, VHT22T, RP5 and cap-and-pin). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8546 10 00 00
HS, 6 digits8546 10
CN (EU)8546 10 00
HTSUS (USA)8546 10 00 00
China customs tariff8546 10 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage are the insulators for distribution networks rated for?

For 5–69 kV networks. For LV there are separate annealed glass insulators A22 and VHC64.

Which conductor cross-sections suit the pin-type insulators VHT20T, VHT22T and RP5?

Bare conductors with a cross-section of 22–228 mm², as well as insulated conductors.

What mechanical load do the cap-and-pin insulators withstand?

Insulators are made for 40 kN (IEC 11) and for 70–120 kN (IEC 16), in standard and fog profiles.