International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Line hardware for HV/EHV overhead lines (coupling, suspension, tension), including for HTLS conductors

The company supplies a full range of hardware for transmission overhead lines of 90–400 kV and above, including UHV and HVDC. It includes hardware for high-temperature low-sag HTLS conductors up to 210 °C and for composite-core conductors.

Voltage class
overhead lines 90–400 kV and above, including UHV/HVDC
Conductors
including HTLS (up to 210 °C) and composite-core
Application
new and reconstructed overhead lines
Production
Le Chambon-Feugerolles (France)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The range covers coupling, suspension and tension hardware for hanging conductors and insulator strings. For HTLS conductors the hardware withstands an operating temperature up to 210 °C, which matters when reconstructing overhead lines with a higher-capacity conductor and no tower replacement. The hardware is used on new and reconstructed lines. It has been supplied for 380 kV TenneT lines and 90 kV lines in Senegal. Production is located in Le Chambon-Feugerolles (France).

Technical specifications

Voltage classoverhead lines 90–400 kV and above, including UHV/HVDC
Conductorsincluding HTLS (up to 210 °C) and composite-core
Applicationnew and reconstructed overhead lines
ProductionLe Chambon-Feugerolles (France)

Request a price and lead time

Line hardware for HV/EHV overhead lines (coupling, suspension, tension), including for HTLS conductors. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)7616 99 90 00
HS, 6 digits7616 99
CN (EU)7616 99 90
HTSUS (USA)7616 99 51 90
China customs tariff7616 99 10 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What overhead line voltage class is the hardware designed for?

For overhead lines of 90–400 kV and above, including UHV and HVDC.

Is the hardware suitable for HTLS conductors?

Yes, there is hardware for HTLS conductors up to 210 °C and for composite-core conductors.

On which lines has the hardware been used?

It has been supplied for 380 kV TenneT lines and 90 kV lines in Senegal.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides