CUSHION-GRIP and Hydro-Québec spacer dampers for split phases
CUSHION-GRIP and Hydro-Québec spacer dampers for split overhead line phases of 2, 3, 4 and 6 conductors. They fix the spacing between the conductors of a phase and damp wind vibration, so separate vibration dampers are not needed.
- CUSHION-GRIP
- phases of 3, 4, 6 conductors; type B to IEC 61854, type C to National Grid requirements
- Hydro-Québec
- phases of 2, 3, 4 conductors; icing and strong wind areas
- Damping
- elastomer elements working in compression
- High-temperature version
- up to 230 °C (Hydro-Québec, on request)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The spacers are tested to IEC 61854 and to utility requirements. CUSHION-GRIP is designed for phases of 3, 4 and 6 conductors, type B complies with IEC 61854, and type C is made to National Grid requirements. The Hydro-Québec model for phases of 2, 3 and 4 conductors works in areas with heavy icing and wind, and a high-temperature version up to 230 °C is available on request. Damping is provided by elastomer elements working in compression. The conductor is fixed with a clamp with an elastomer and a quarter-turn retainer, or with helical armor.
Technical specifications
| CUSHION-GRIP | phases of 3, 4, 6 conductors; type B to IEC 61854, type C to National Grid requirements |
|---|---|
| Hydro-Québec | phases of 2, 3, 4 conductors; icing and strong wind areas |
| Damping | elastomer elements working in compression |
| High-temperature version | up to 230 °C (Hydro-Québec, on request) |
| Attachment | clamp with elastomer and quarter-turn retainer, or helical armor |
Request a price and lead time
CUSHION-GRIP and Hydro-Québec spacer dampers for split phases. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 7616 99 90 00 |
|---|---|
| HS, 6 digits | 7616 99 |
| CN (EU) | 7616 99 90 |
| HTSUS (USA) | 7616 99 51 90 |
| China customs tariff | 7616 99 10 90 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
For phases with how many conductors are the spacers made?
CUSHION-GRIP for phases of 3, 4 and 6 conductors, and the Hydro-Québec model for phases of 2, 3 and 4 conductors. The model is chosen for the phase design.
What standard are the spacers tested to?
IEC 61854 and utility requirements. Type C of CUSHION-GRIP meets National Grid requirements.
Are separate vibration dampers needed with the spacers?
No, the elastomer elements damp wind vibration. A high-temperature version up to 230 °C is available on request for the Hydro-Québec model.
Similar equipment from other manufacturers