Busbar supports for tubes and conductors on post insulators
Support clamps for tubular busbars and conductors on post insulators: fixed and sliding (to absorb thermal expansion of the bus), plus supports for bundle T-taps.
- Designs
- supports for tubes and for conductors; fixed and sliding; bundle T-connector supports
- Conductor supports (SHB)
- conductor Ø16–50 mm, base 76–225 mm, M8–M10
- Options
- anti-vibration neoprene coating; other base sizes and holes on request
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Support clamps for tubular busbars and conductors on post insulators: fixed and sliding (to absorb thermal expansion of the bus), plus supports for bundle T-taps.
Features: Bodies are cast from primary aluminium alloy EN AC-42100 T6, copper parts from EN 1982 alloys; hardware is A2-70 stainless steel (DIN 933, EN ISO 3506-1) with PTFE-based anti-seize coated nuts. The design rule is that at full load the connector runs cooler than the conductor. Design and type testing follow ANSI/NEMA CC1, IEC and BS EN.
Specifications: Designs — supports for tubes and for conductors; fixed and sliding; bundle T-connector supports; Conductor supports (SHB) — conductor Ø16–50 mm, base 76–225 mm, M8–M10; Options — anti-vibration neoprene coating; other base sizes and holes on request.
Applications: outdoor substations 110–750 kV, aluminium tube and conductor busbars, connection of equipment.
Selection by conductor and tube diameters, design and quantity is made from an inquiry form; delivery time and terms are confirmed by our manager.
Technical specifications
| Designs | supports for tubes and for conductors; fixed and sliding; bundle T-connector supports |
|---|---|
| Conductor supports (SHB) | conductor Ø16–50 mm, base 76–225 mm, M8–M10 |
| Options | anti-vibration neoprene coating; other base sizes and holes on request |
Part numbers
Show all part numbers (340)
SHB.03.300, SHB.05.300, SHB.89.300, SHB.03.310, SHB.05.310, SHB.89.310, SHB.03.320, SHB.05.320, SHB.89.320, SHB.03.330, SHB.05.330, SHB.89.330, SHDB.100.010, SHDB.100.020, SHDB.100.030, SHDB.100.040, SHDB.100.050, SHDB.100.060, SHDB.100.070, SHDB.100.080, SHDB.100.090, SHDB.100.100, SHDB.100.110, SHDB.100.120, SHDB.100.130, SHDB.100.140, SHDB.100.150, SHDB.100.160, SHDB.100.170, SHDB.100.180, SHDB.200.010, SHDB.200.020, SHDB.200.030, SHDB.200.040, SHDB.200.050, SHDB.200.060, SHDB.200.070, SHDB.200.080, SHDB.200.090, SHDB.200.200, SHDB.200.110, SHDB.200.120, SHDB.200.130, SHDB.200.140, SHDB.200.150, SHDB.200.160, SHDB.200.170, SHDB.200.180, SLHDB.100.010, SLHDB.100.020, SLHDB.100.030, SLHDB.100.040, SLHDB.100.050, SLHDB.100.060, SLHDB.100.070, SLHDB.100.080, SLHDB.100.090, SLHDB.100.100, SLHDB.100.110, SLHDB.100.120, SLHDB.100.130, SLHDB.100.140, SLHDB.100.150, SLHDB.100.160, SLHDB.100.170, SLHDB.100.180, SLHDB.200.010, SLHDB.200.020, SLHDB.200.030, SLHDB.200.040, SLHDB.200.050, SLHDB.200.060, SLHDB.200.070, SLHDB.200.080, SLHDB.200.090, SLHDB.200.200, SLHDB.200.110, SLHDB.200.120, SLHDB.200.130, SLHDB.200.140, SLHDB.200.150, SLHDB.200.160, SLHDB.200.170, SLHDB.200.180, SVHB.02.03.300, SVHB.02.05.300, SVHB.02.89.300, SVHB.02.03.310, SVHB.02.05.310, SVHB.02.89.310, SVHB.02.03.320, SVHB.02.05.320, SVHB.02.89.320, SVHB.02.03.330, SVHB.02.05.330, SVHB.02.89.330, SHB.03.010, SHB.05.010, SHB.89.010, SHB.03.020, SHB.05.020, SHB.89.020, SHB.03.030, SHB.05.030, SHB.89.030, SHB.03.040, SHB.05.040, SHB.89.040, SHB.03.050, SHB.05.050, SHB.89.050, SHB.03.060, SHB.05.060, SHB.89.060, SHB.03.070, SHB.05.070, SHB.89.070, SHB.03.080, SHB.05.080, SHB.89.080, SHB.03.090, SHB.05.090, SHB.89.090, SHB.03.100, SHB.05.100, SHB.89.100, SHB.03.500, SHB.05.500, SHB.89.500, SHB.03.510, SHB.05.510, SHB.89.510, SHB.03.520, SHB.05.520, SHB.89.520, SHB.03.530, SHB.05.530, SHB.89.530, SHB.03.540, SHB.05.540, SHB.89.540, SHB.03.550, SHB.05.550, SHB.89.550, SHB.03.560, SHB.05.560, SHB.89.560, SHB.03.570, SHB.05.570, SHB.89.570, SHSB.03.010, SHSB.05.010, SHSB.89.010, SHSB.03.020, SHSB.05.020, SHSB.89.020, SHSB.03.030, SHSB.05.030, SHSB.89.030, SHSB.03.040, SHSB.05.040, SHSB.89.040, SHSB.03.050, SHSB.05.050, SHSB.89.050, SHSB.03.060, SHSB.05.060, SHSB.89.060, SHSB.03.070, SHSB.05.070, SHSB.89.070, SHSB.03.080, SHSB.05.080, SHSB.89.080, SHSB.03.090, SHSB.05.090, SHSB.89.090, SHSB.03.500, SHSB.05.500, SHSB.89.500, SHSB.03.510, SHSB.05.510, SHSB.89.510, SHSB.03.520, SHSB.05.520, SHSB.89.520, SHSB.03.530, SHSB.05.530, SHSB.89.530, SHSB.03.540, SHSB.05.540, SHSB.89.540, SHSB.03.550, SHSB.05.550, SHSB.89.550, SHSB.03.560, SHSB.05.560, SHSB.89.560, SHSB.03.570, SHSB.05.570, SHSB.89.570, SSHSB.03.010, SSHSB.05.010, SSHSB.89.010, SSHSB.03.020, SSHSB.05.020, SSHSB.89.020, SSHSB.03.030, SSHSB.05.030, SSHSB.89.030, SSHSB.03.040, SSHSB.05.040, SSHSB.89.040, SSHSB.03.050, SSHSB.05.050, SSHSB.89.050, SSHSB.03.060, SSHSB.05.060, SSHSB.89.060, SSHSB.03.070, SSHSB.05.070, SSHSB.89.070, SSHSB.03.080, SSHSB.05.080, SSHSB.89.080, SSHSB.03.090, SSHSB.05.090, SSHSB.89.090, SSHSB.03.500, SSHSB.05.500, SSHSB.89.500, SSHSB.03.510, SSHSB.05.510, SSHSB.89.510, SSHSB.03.520, SSHSB.05.520, SSHSB.89.520, SSHSB.03.530, SSHSB.05.530, SSHSB.89.530, SSHSB.03.540, SSHSB.05.540, SSHSB.89.540, SSHSB.03.550, SSHSB.05.550, SSHSB.89.550, SSHSB.03.560, SSHSB.05.560, SSHSB.89.560, SSHSB.03.570, SSHSB.05.570, SSHSB.89.570, SXHB.05.010, SXHB.89.010, SXHB.05.020, SXHB.89.020, SXHB.05.030, SXHB.89.030, SXHB.05.040, SXHB.89.040, SXHB.05.050, SXHB.89.050, SXHB.05.060, SXHB.89.060, SXHB.05.070, SXHB.89.070, SXHB.05.080, SXHB.89.080, SXHB.05.090, SXHB.89.090, SXHB.05.500, SXHB.89.500, SXHB.05.510, SXHB.89.510, SXHB.05.520, SXHB.89.520, SXHB.05.530, SXHB.89.530, SXHB.05.540, SXHB.89.540, SXHB.05.550, SXHB.89.550, SXHB.05.560, SXHB.89.560, SXHB.05.570, SXHB.89.570, SVHB.01.03.010, SVHB.01.05.010, SVHB.01.89.010, SVHB.01.03.020, SVHB.01.05.020, SVHB.01.89.020, SVHB.01.03.030, SVHB.01.05.030, SVHB.01.89.030, SVHB.01.03.040, SVHB.01.05.040, SVHB.01.89.040, SVHB.01.03.050, SVHB.01.05.050, SVHB.01.89.050, SVHB.01.03.060, SVHB.01.05.060, SVHB.01.89.060, SVHB.01.03.070, SVHB.01.05.070, SVHB.01.89.070, SVHB.01.03.080, SVHB.01.05.080, SVHB.01.89.080, SVHB.01.03.090, SVHB.01.05.090, SVHB.01.89.090, SVHB.01.03.100, SVHB.01.05.100, SVHB.01.89.100, SVHB.01.03.500, SVHB.01.05.500, SVHB.01.89.500, SVHB.01.03.510, SVHB.01.05.510, SVHB.01.89.510, SVHB.01.03.520, SVHB.01.05.520, SVHB.01.89.520, SVHB.01.03.530, SVHB.01.05.530, SVHB.01.89.530, SVHB.01.03.540, SVHB.01.05.540, SVHB.01.89.540, SVHB.01.03.550, SVHB.01.05.550, SVHB.01.89.550, SVHB.01.03.560, SVHB.01.05.560, SVHB.01.89.560, SVHB.01.03.570, SVHB.01.05.570, SVHB.01.89.570