Bolted substation clamps 110–400 kV
Bolted aluminium clamps for flexible substation busbars and for connecting conductors to equipment terminals: straight, 45° and 90° angle, T, Y and L taps, through clamps, Al/Cu transition clamps, bundle clamps and clamps for 2×AL 887.
- Voltage
- 110 and 400 kV
- Rated current
- 1000–4000 A depending on type
- Short-circuit current (example)
- 50 kA
- Material
- body, cover, pad — aluminium; hardware — hot-dip galvanised steel to PN-EN ISO 1461
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Bolted aluminium clamps for flexible substation busbars and for connecting conductors to equipment terminals: straight, 45° and 90° angle, T, Y and L taps, through clamps, Al/Cu transition clamps, bundle clamps and clamps for 2×AL 887. Made for standard AFL-6, AFL-8 and AL conductors.
Specifications: Voltage — 110 and 400 kV; Rated current — 1000–4000 A depending on type; Short-circuit current (example) — 50 kA; Material — body, cover, pad — aluminium; hardware — hot-dip galvanised steel to PN-EN ISO 1461; Conductors (example) — AFL-6 185 (Ø19.2 mm), AFL-6 240 (Ø21.7 mm), AFL-8 525, 2×AL 887.
Applications: 110–400 kV substations: flexible busbars, connection of breakers, disconnectors, CTs and VTs.
Selection by conductor type, loads and design is made from an inquiry form; delivery time and terms are confirmed by our manager.
Technical specifications
| Voltage | 110 and 400 kV |
|---|---|
| Rated current | 1000–4000 A depending on type |
| Short-circuit current (example) | 50 kA |
| Material | body, cover, pad — aluminium; hardware — hot-dip galvanised steel to PN-EN ISO 1461 |
| Conductors (example) | AFL-6 185 (Ø19.2 mm), AFL-6 240 (Ø21.7 mm), AFL-8 525, 2×AL 887 |
Part numbers
Show all part numbers (237)
23200.05/15, 23200.05/20, 23200.05/25, 23200.05/30, 23200.05/35, 23200.05/40, 23200.06/15, 23200.06/20, 23200.06/25, 23200.06/30, 23200.06/35, 23200.06/40, 23400.07/15, 23400.07/20, 23400.07/25, 23400.07/30, 23400.07/35, 23400.07/40, 23400.09/15, 23400.09/20, 23400.09/25, 23400.09/30, 23400.09/35, 23400.09/40, 23201.0104, 23201.0105, 23201.0106, 23221.0104, 23221.0105, 23221.0106, 23207.0104, 23207.0105, 23207.0106, 23202.0104, 23202.0105, 23202.0106, 23222.0104, 23222.0105, 23222.0106, 23208.0104, 23208.0105, 23208.0106, 23203.0104, 23203.0105, 23203.0106, 23223.0104, 23223.0105, 23223.0106, 23209.0104, 23209.0105, 23209.0106, 23401.0107, 23401.0108, 23401.0109, 23604.0128, 23401.0107HV, 23401.0108HV, 23401.0109HV, 23604.0128HV, 23421.0107, 23421.0108, 23421.0109, 23621.0128, 23421.0107HV, 23421.0108HV, 23421.0109HV, 23621.0128HV, 23407.0107, 23407.0108, 23407.0109, 23607.0128, 23407.0107HV, 23407.0108HV, 23407.0109HV, 23607.0128HV, 23402.0107, 23402.0108, 23402.0109, 23605.0128, 23402.0107HV, 23402.0108HV, 23402.0109HV, 23605.0128HV, 23422.0107, 23422.0108, 23422.0109, 23622.0128, 23422.0107HV, 23422.0108HV, 23422.0109HV, 23622.0128HV, 23408.0107, 23408.0108, 23408.0109, 23608.0128, 23408.0107HV, 23408.0108HV, 23408.0109HV, 23608.0128HV, 23403.0107, 23403.0108, 23403.0109, 23606.0128, 23403.0107HV, 23403.0108HV, 23403.0109HV, 23606.0128HV, 23423.0107, 23423.0108, 23423.0109, 23623.0128, 23423.0107HV, 23423.0108HV, 23423.0109HV, 23623.0128HV, 23409.0107, 23409.0108, 23409.0109, 23609.0128, 23409.0107HV, 23409.0108HV, 23409.0109HV, 23609.0128HV, 23201.0404, 23201.0406, 23201.0505, 23201.0506, 23201.0605, 23201.0606, 23401.0705, 23401.0706, 23401.0805, 23401.0806, 23401.0904, 23401.0905, 23401.0906, 23604.2805, 23604.2806, 23401.0705HV, 23401.0706HV, 23401.0805HV, 23401.0806HV, 23401.0905HV, 23401.0906HV, 23604.2805HV, 23604.2806HV, 23436.0707, 23436.0708, 23436.0709, 23436.0807, 23436.0808, 23436.0809, 23436.0907, 23436.0908, 23436.0909, 23401.0928, 23604.2807, 23604.2809, 23604.2828, 23401.0928HV, 23604.2807HV, 23604.2809HV, 23604.2828HV, 23219.0501, 23219.0601, 23419.0701, 23419.0801, 23419.0901, 23419.2801, 23419.0701HV, 23419.0801HV, 23419.0901HV, 23620.2801HV, 23210.0505, 23210.0506, 23210.0605, 23210.0606, 23210.0507, 23210.0508, 23210.0509, 23210.0528, 23210.0607, 23210.0608, 23210.0609, 23210.0628, 23410.0705, 23410.0706, 23410.0805, 23410.0806, 23410.0905, 23410.0906, 23611.2805, 23611.2806, 23410.0705HV, 23410.0706HV, 23410.0805HV, 23410.0806HV, 23410.0905HV, 23410.0906HV, 23611.2805HV, 23611.2806HV, 23410.0707, 23410.0708, 23410.0709, 23410.0728, 23410.0807, 23410.0808, 23410.0809, 23410.0828, 23410.0907, 23410.0908, 23410.0909, 23410.0928, 23611.2807, 23611.2808, 23611.2809, 23611.2828, 23410.0707HV, 23410.0708HV, 23410.0709HV, 23410.0728HV, 23410.0807HV, 23410.0808HV, 23410.0809HV, 23410.0828HV, 23410.0907HV, 23410.0908HV, 23410.0909HV, 23410.0928HV, 23611.2807HV, 23611.2808HV, 23611.2809HV, 23611.2828HV, 23440.0909, 23440.0928, 23640.2809, 23640.2828
Request a price and lead time
Bolted substation clamps 110–400 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Similar equipment from other manufacturers