International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Bolted substation clamps 110–400 kV

Bolted aluminium clamps for flexible substation busbars and for connecting conductors to equipment terminals: straight, 45° and 90° angle, T, Y and L taps, through clamps, Al/Cu transition clamps, bundle clamps and clamps for 2×AL 887.

Voltage
110 and 400 kV
Rated current
1000–4000 A depending on type
Short-circuit current (example)
50 kA
Material
body, cover, pad — aluminium; hardware — hot-dip galvanised steel to PN-EN ISO 1461

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Bolted aluminium clamps for flexible substation busbars and for connecting conductors to equipment terminals: straight, 45° and 90° angle, T, Y and L taps, through clamps, Al/Cu transition clamps, bundle clamps and clamps for 2×AL 887. Made for standard AFL-6, AFL-8 and AL conductors.

Specifications: Voltage — 110 and 400 kV; Rated current — 1000–4000 A depending on type; Short-circuit current (example) — 50 kA; Material — body, cover, pad — aluminium; hardware — hot-dip galvanised steel to PN-EN ISO 1461; Conductors (example) — AFL-6 185 (Ø19.2 mm), AFL-6 240 (Ø21.7 mm), AFL-8 525, 2×AL 887.

Applications: 110–400 kV substations: flexible busbars, connection of breakers, disconnectors, CTs and VTs.

Selection by conductor type, loads and design is made from an inquiry form; delivery time and terms are confirmed by our manager.

Technical specifications

Voltage110 and 400 kV
Rated current1000–4000 A depending on type
Short-circuit current (example)50 kA
Materialbody, cover, pad — aluminium; hardware — hot-dip galvanised steel to PN-EN ISO 1461
Conductors (example)AFL-6 185 (Ø19.2 mm), AFL-6 240 (Ø21.7 mm), AFL-8 525, 2×AL 887

Part numbers

Show all part numbers (237)

23200.05/15, 23200.05/20, 23200.05/25, 23200.05/30, 23200.05/35, 23200.05/40, 23200.06/15, 23200.06/20, 23200.06/25, 23200.06/30, 23200.06/35, 23200.06/40, 23400.07/15, 23400.07/20, 23400.07/25, 23400.07/30, 23400.07/35, 23400.07/40, 23400.09/15, 23400.09/20, 23400.09/25, 23400.09/30, 23400.09/35, 23400.09/40, 23201.0104, 23201.0105, 23201.0106, 23221.0104, 23221.0105, 23221.0106, 23207.0104, 23207.0105, 23207.0106, 23202.0104, 23202.0105, 23202.0106, 23222.0104, 23222.0105, 23222.0106, 23208.0104, 23208.0105, 23208.0106, 23203.0104, 23203.0105, 23203.0106, 23223.0104, 23223.0105, 23223.0106, 23209.0104, 23209.0105, 23209.0106, 23401.0107, 23401.0108, 23401.0109, 23604.0128, 23401.0107HV, 23401.0108HV, 23401.0109HV, 23604.0128HV, 23421.0107, 23421.0108, 23421.0109, 23621.0128, 23421.0107HV, 23421.0108HV, 23421.0109HV, 23621.0128HV, 23407.0107, 23407.0108, 23407.0109, 23607.0128, 23407.0107HV, 23407.0108HV, 23407.0109HV, 23607.0128HV, 23402.0107, 23402.0108, 23402.0109, 23605.0128, 23402.0107HV, 23402.0108HV, 23402.0109HV, 23605.0128HV, 23422.0107, 23422.0108, 23422.0109, 23622.0128, 23422.0107HV, 23422.0108HV, 23422.0109HV, 23622.0128HV, 23408.0107, 23408.0108, 23408.0109, 23608.0128, 23408.0107HV, 23408.0108HV, 23408.0109HV, 23608.0128HV, 23403.0107, 23403.0108, 23403.0109, 23606.0128, 23403.0107HV, 23403.0108HV, 23403.0109HV, 23606.0128HV, 23423.0107, 23423.0108, 23423.0109, 23623.0128, 23423.0107HV, 23423.0108HV, 23423.0109HV, 23623.0128HV, 23409.0107, 23409.0108, 23409.0109, 23609.0128, 23409.0107HV, 23409.0108HV, 23409.0109HV, 23609.0128HV, 23201.0404, 23201.0406, 23201.0505, 23201.0506, 23201.0605, 23201.0606, 23401.0705, 23401.0706, 23401.0805, 23401.0806, 23401.0904, 23401.0905, 23401.0906, 23604.2805, 23604.2806, 23401.0705HV, 23401.0706HV, 23401.0805HV, 23401.0806HV, 23401.0905HV, 23401.0906HV, 23604.2805HV, 23604.2806HV, 23436.0707, 23436.0708, 23436.0709, 23436.0807, 23436.0808, 23436.0809, 23436.0907, 23436.0908, 23436.0909, 23401.0928, 23604.2807, 23604.2809, 23604.2828, 23401.0928HV, 23604.2807HV, 23604.2809HV, 23604.2828HV, 23219.0501, 23219.0601, 23419.0701, 23419.0801, 23419.0901, 23419.2801, 23419.0701HV, 23419.0801HV, 23419.0901HV, 23620.2801HV, 23210.0505, 23210.0506, 23210.0605, 23210.0606, 23210.0507, 23210.0508, 23210.0509, 23210.0528, 23210.0607, 23210.0608, 23210.0609, 23210.0628, 23410.0705, 23410.0706, 23410.0805, 23410.0806, 23410.0905, 23410.0906, 23611.2805, 23611.2806, 23410.0705HV, 23410.0706HV, 23410.0805HV, 23410.0806HV, 23410.0905HV, 23410.0906HV, 23611.2805HV, 23611.2806HV, 23410.0707, 23410.0708, 23410.0709, 23410.0728, 23410.0807, 23410.0808, 23410.0809, 23410.0828, 23410.0907, 23410.0908, 23410.0909, 23410.0928, 23611.2807, 23611.2808, 23611.2809, 23611.2828, 23410.0707HV, 23410.0708HV, 23410.0709HV, 23410.0728HV, 23410.0807HV, 23410.0808HV, 23410.0809HV, 23410.0828HV, 23410.0907HV, 23410.0908HV, 23410.0909HV, 23410.0928HV, 23611.2807HV, 23611.2808HV, 23611.2809HV, 23611.2828HV, 23440.0909, 23440.0928, 23640.2809, 23640.2828

Request a price and lead time

Bolted substation clamps 110–400 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.