International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

KSTAR SPC01, power control box (limitation and zero export) for grid-tied inverters 3–125 kW

The KSTAR SPC01 limits the feed-in of a solar plant to the grid or performs zero export in accordance with local codes. It works with KSTAR three-phase grid-tied inverters of 3–125 kW over RS-485, up to 80 inverters per box. The zero export response time is less than 2 s, and the regulation accuracy is 3 %.

Purpose
power limitation and zero export
Compatible inverters
KSTAR three-phase grid-tied, 3–125 kW, over RS-485
Number of inverters
up to 80
Communication range to inverters
up to 1000 m

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

USK ENERGY supplies KSTAR equipment as an official partner of the manufacturer. All KSTAR products

Description

The SPC01 power control box from KSTAR performs power limitation or zero export in accordance with local grid codes. It works with KSTAR three-phase grid-tied photovoltaic inverters of 3–125 kW, and communication runs over the RS-485 interface. A built-in smart meter measures power in real time on the grid connection side of the plant. Export limitation is needed where the grid operator sets a feed-in limit or prohibits it altogether. Therefore the box stands between the inverters and the connection point and regulates their power according to the readings of the built-in meter. Paired with KSTAR inverters, a communication range of up to 1000 m is important for large distributed plants, where the inverters are located far from the connection point.

The box is designed for large distributed plants. Up to 80 inverters can be connected to one SPC01. For this there are 5 RS-485 ports, and each terminal serves up to 16 inverters. The length of the communication line to the inverters reaches 1000 m, so the box can be placed near the connection point, rather than next to each inverter.

The response time of the zero export function is less than 2 s, and the regulation accuracy is 3 %, which meets the requirements of the grid codes. For safety, automatic shutdown is provided when communication with the inverters is lost. Firmware is updated remotely, and operating data is transmitted to a cloud server in real time.

For local commissioning there is Bluetooth and light status indication, so the installer sees the status of the box without a laptop. The input voltage is 230 V (L-N) / 400 V (L-L), the range is 173–480 V, the frequency is 45–65 Hz, and the connection is 3W+N+PE. The enclosure has an IP65 protection rating, is suitable for outdoor installation, and is mounted on a wall or in a rack.

Application: rooftop and ground-mounted solar plants connected to grids with export limitation, where connection is impossible or unprofitable without power control. According to the manufacturer description, the box is suitable for residential, commercial and industrial solar systems. The box works both on a roof and on the ground, and the equipment is fixed on a wall or in a rack next to the inverters.

Technical specifications

Purposepower limitation and zero export
Compatible invertersKSTAR three-phase grid-tied, 3–125 kW, over RS-485
Number of invertersup to 80
Communication range to invertersup to 1000 m
Zero export response timeless than 2 s
Regulation accuracy3 %
Input230 V (L-N) / 400 V (L-L), 173–480 V, 45–65 Hz, 3W+N+PE
RS-485 ports5
Protection ratingIP65
Mountingwall / rack

Request a price and lead time

KSTAR SPC01, power control box (limitation and zero export) for grid-tied inverters 3–125 kW. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many inverters can be connected to the KSTAR SPC01?

Up to 80 inverters per box. The box has 5 RS-485 ports, and up to 16 inverters are connected to each terminal.

Which inverters does the SPC01 work with?

With KSTAR three-phase grid-tied photovoltaic inverters of 3–125 kW over RS-485. The length of the communication line is up to 1000 m.

What are the speed and accuracy of zero export regulation?

The response time is less than 2 s, and the regulation accuracy is 3 %. If communication is lost, the box automatically switches off the inverters.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides