International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

G2S and G2A — single-phase hybrid inverters, 3–10 kW, for home energy storage systems

The G2S series is single-phase hybrid inverters with a power of 3 to 10 kW for residential buildings with solar panels and a 48 V battery.

Grid voltage
230 V, 176–270 V, 50/60 Hz
MPPT range
100–430 V
Battery voltage
40–58 V
Dimensions
486 × 231 × 530 mm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The G2S series is single-phase hybrid inverters with a power of 3 to 10 kW for residential buildings with solar panels and a 48 V battery. The unit powers the house from the panels and the battery, charges the battery from the grid, and switches to backup when the grid fails. The range includes 3–6 kW and 8–10 kW variants, as well as the G2A series at 3–6 kW, so the power is selected according to the size of the house and the number of panels.

Main features: two MPPT trackers, range 100–430 V, maximum PV 550 V; battery 40–58 V (nominal 48 V), lithium-ion or lead-acid; charging mode self-tuning based on BMS data via CAN; overload: 110 % for 10 minutes, 150 % for 100 ms; fan cooling, IP65 protection; European efficiency not lower than 96.5 %.

Versions in the series: G2S 3–6 kW, G2S 8–10 kW, G2A 3–6 kW.

Technical data (depend on the version): grid voltage — 230 V, 176–270 V, 50/60 Hz; MPPT range — 100–430 V; battery voltage — 40–58 V; dimensions — 486 × 231 × 530 mm; weight — about 20.5 kg; degree of protection — IP65; operating temperature — −25…+60 °C.

Applications: residential houses with solar panels and a battery; summer houses and country homes with an unstable grid; backup power in case of outages.

The card provides the technical description and the specification table. The specific version, power, battery voltage, equipment set and communication protocols are selected for each project; please clarify the parameters with a USK ENERGY manager. Supplied to order, with documents for customs clearance, and with assistance in selecting batteries and the control system.

Technical specifications

Grid voltage230 V, 176–270 V, 50/60 Hz
MPPT range100–430 V
Battery voltage40–58 V
Dimensions486 × 231 × 530 mm
Weightabout 20.5 kg
Degree of protectionIP65
Operating temperature−25…+60 °C

Request a price and lead time

G2S and G2A — single-phase hybrid inverters, 3–10 kW, for home energy storage systems. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides