International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

HRH / HRR — high-voltage wound-rotor induction motors up to 8 MW, 15 kV

HRH and HRR are high-voltage wound-rotor induction motors with slip rings, rated up to 8000 kW at voltage up to 15 kV. The wound rotor gives high starting torque at limited starting current, and the speed of a heavy machine can be controlled. HRH has open air cooling, HRR has closed tube cooling.

Power
up to 8000 kW
Voltage
up to 15 kV
Speed
up to 1800 rpm
HRH (air cooling)
IC11, IC21, IC31; frame size 400–900; IP23

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The three-phase rotor winding is made with the same number of poles as the stator winding, connected in star or delta and brought out to three slip rings. A starting rheostat or, in the doubly-fed scheme, a converter is connected to the rings. After acceleration the rheostat is cut out, the rings are short-circuited, and the motor runs as an ordinary induction machine. The speed of both series is up to 1800 rpm. The motors allow direct starting, soft starting and operation from a VFD for voltage up to 15 kV, insulation class F or H.

HRH is cooled open, by air per IC11, IC21 or IC31 with one-sided or two-sided air supply. IEC frame sizes are 400–900, degree of protection up to IP23, mounting arrangements IM B3 (IM1001) and IM V1 (IM3011). HRR is enclosed, with a tubular air-to-air heat exchanger IC511. Its frame sizes are 500–1250, protection up to IP55, and it has three mounting arrangements: IM B3, IM B5 and IM V1. For dusty workshops the enclosed HRR is the suitable choice, while for clean machine halls HRH is sufficient.

Both series are built to IEC 60034 or NEMA MG1. For hazardous areas, marine installations and nuclear power plants a special design with ATEX and IECEx certification is available. The motors are assembled at the manufacturer's plant in Preding (Austria). Rotor and stator windings of high-voltage machines are also made by the group's subsidiaries in Bosnia and India.

A wound rotor is justified where the machine is hard to accelerate. These are ball and rod mills, crushers, fans with a large moment of inertia, compressors and pumps in the cement, mining, metallurgical and power industries. Another case is a weak grid, where direct starting of a squirrel-cage motor is difficult because of the high starting current. HRH and HRR are suitable to replace high-voltage wound-rotor motors АКН, АКЗ, ДАФ and their equivalents.

For a replacement, specify the power, stator voltage, rotor parameters, speed, starting method and connection dimensions. The rotor data are needed to match the new motor to the existing starting rheostat or converter. The maintenance of the slip ring and brush assembly is discussed separately, since the overhaul interval depends on it.

Technical specifications

Powerup to 8000 kW
Voltageup to 15 kV
Speedup to 1800 rpm
HRH (air cooling)IC11, IC21, IC31; frame size 400–900; IP23
HRR (tube cooling)IC511; frame size 500–1250; up to IP55
StartingDOL; soft start and VFD
InsulationF or H
MountingIM B3, IM V1 (HRR also IM B5)
StandardsIEC 60034, NEMA MG1; ATEX, IECEx

Request a price and lead time

HRH / HRR — high-voltage wound-rotor induction motors up to 8 MW, 15 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8501 53 81 00
8501 53 94 00
8501 53 99 00
HS, 6 digits8501 53
CN (EU)8501 53 81
8501 53 94
8501 53 99
HTSUS (USA)8501 53 40 00
8501 53 80 00
China customs tariff8501 53 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What power and voltage do the HRH and HRR motors have?

Up to 8000 kW at voltage up to 15 kV, speed up to 1800 rpm.

How do HRH and HRR differ?

HRH is cooled open per IC11, IC21 or IC31, with protection IP23 and frame sizes 400–900. HRR is enclosed, with an IC511 tubular heat exchanger, protection up to IP55 and frame sizes 500–1250.

Which wound-rotor motors can be replaced by the HRH and HRR series?

High-voltage motors АКН, АКЗ, ДАФ and their equivalents. The series suit mills, crushers and fans with a large moment of inertia.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides