SG-6 safety spark gap, 100 V trigger, for cable test and fault-location work

The SG-6 is a protective spark gap for crews working on de-energised feeders and power cables where back feed could occur. It fires at 100 V, copes with high fault currents and is there first of all to keep the operator safe, with the test gear protected as well.

Model
SG-6
Type
safety spark gap
Trigger voltage
100 V
Working element
replaceable mica discs

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Mica discs form the working element of the SG-6, and they are the part that gets replaced after the gap has operated; the housing and connections stay in service. Keeping a set of spare discs with the unit, and inspecting them before each job, is sensible practice.

On a cable network, a line that has been switched out is not always dead. Voltage can arrive from another source or from the load side, which is what engineers call back feed. The SG-6 is connected between the conductor and earth so that, if this happens, the gap takes the energy rather than the person or the instrument on the line.

The trigger level is 100 V. Below it the gap stays open and has no effect on measurements; once the voltage rises above it, the gap breaks down and current flows to earth through the device. It is built to withstand high fault currents, so a single abnormal event does not put it out of action.

The unit is intended to be used alongside the Ammeter Clear Test Set, model AC-5, which checks whether a feeder has any shorts or earths applied. It belongs to the manufacturer's range of equipment for power cable testing and for underground cable networks at substations. Wiring follows the test set arrangement and the site's own electrical safety rules.

Technical specifications

ModelSG-6
Typesafety spark gap
Trigger voltage100 V
Working elementreplaceable mica discs
Fault currentdesigned to withstand high fault currents
CompatibilityAmmeter Clear Test Set, model AC-5
Purposeprotection of staff and equipment against back feed

Request a price and lead time

SG-6 safety spark gap, 100 V trigger, for cable test and fault-location work. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

At what voltage does the SG-6 operate?

The trigger voltage is 100 V. Below that level the gap does not conduct.

Which parts are replaced after the gap has fired?

The mica discs are the replaceable parts; the housing and connections are retained.

What equipment is the SG-6 used with?

It is used together with the Ammeter Clear Test Set, model AC-5, which checks a feeder for shorts and applied earths.