STCS PLUS Module for Single-Connection Power Transformer Tests

The STCS PLUS extends the STS 5000 and STS 4000 systems and runs the main power transformer tests automatically after a single connection. Only two multicore cables, one for the primary side and one for the secondary, run to the transformer.

Compatibility
STS 5000, STS 4000
Purpose
power transformer testing
Automatic tests
turns ratio at each tap, no-load current, vector group, short-circuit impedance, leakage reactance, winding resistance, dynamic OLTC test, demagnetisation
Cables
two multicore cables, one for the primary side and one for the secondary, on reels

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The STCS PLUS is used for tests on power transformers at substations, working together with the STS 5000 and STS 4000 multifunction systems. After one connection, the module carries out the main transformer tests automatically: turns ratio at each tap, no-load current, vector group, short-circuit impedance and leakage reactance, winding resistance, dynamic tap changer testing and core demagnetisation.

Only two multicore cables run to the transformer, one for the primary side and one for the secondary, and each is wound on its own reel. The cable is chosen to suit the size of the transformer under test. Two junction boxes are supplied to simplify connecting the cables to the transformer bushings, and one of them carries a high-current switch for automatic measurement of short-circuit impedance.

Running every test from a single connection cuts the time spent on site and lowers the chance of wiring errors. The housing is a black plastic case with handles, and the lid can be removed for easy access. The maximum test voltage of the module is 400 V. The STCS PLUS is offered as an optional kit for the base STS system, which sets and runs the test sequence while the module switches the circuits between stages.

The STS systems carry out tests on current, voltage and power transformers, with IEC61869-2 and IEC61869-3 along with EN 60076-1, ANSI/IEEE C57.13.1 and other standards. The equipment complies with Directives 2004/108/EC and 2006/95/EC, EN61326-1:2006 and CEI EN 61010-1:2010.

Technical specifications

CompatibilitySTS 5000, STS 4000
Purposepower transformer testing
Automatic teststurns ratio at each tap, no-load current, vector group, short-circuit impedance, leakage reactance, winding resistance, dynamic OLTC test, demagnetisation
Cablestwo multicore cables, one for the primary side and one for the secondary, on reels
Junction boxestwo, one fitted with a high-current switch
Maximum test voltage400 V
Housingblack plastic case with handles
Lidremovable
ComplianceDirectives 2004/108/EC and 2006/95/EC, EN 61326-1:2006, CEI EN 61010-1:2010

Request a price and lead time

STCS PLUS Module for Single-Connection Power Transformer Tests. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many cables are needed to connect the transformer?

Two multicore cables, one for the primary side and one for the secondary, each wound on its own reel and linked through two junction boxes.

How does the STCS PLUS differ from the STCS?

The STCS PLUS runs the full set of power transformer tests from one connection, including short-circuit impedance and demagnetisation, while the STCS automates turns ratio, winding resistance and tap changer tests.

How is short-circuit impedance measured automatically?

One junction box has a high-current switch that short-circuits the transformer side without any manual reconnection.