46CP Combined AC/DC Hi-Potential Test System, Up to 100 kV AC and 120 kV DC

A mobile 46CP series set that applies high AC and DC voltage to electrical equipment for insulation tests. There are two models, up to 50 kV AC and 70 kV DC, and up to 100 kV AC and 120 kV DC, each built as three sections on a hand trolley.

Model 46CP50/70-2/10, AC output
~0–50 kV, 40 mA
Model 46CP50/70-2/10, DC output
~0–70 kV, 10 mA
Model 46CP100/120-3.75/10, AC output
~0–100 kV, 37.5 mA
Model 46CP100/120-3.75/10, DC output
~0–120 kV, 10 mA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 46CP series combines an AC and a DC test voltage source in one set. It serves insulation tests on cables, circuit breakers, generators, metal-enclosed switchgear, insulating materials, electric motors, protective devices, reclosers, transformers, vacuum interrupters and complete switchgear assemblies. One unit replaces separate AC and DC equipment where a site needs both types of test.

The 46CP50/70-2/10 model delivers approximately 0 to 50 kV AC at 40 mA and approximately 0 to 70 kV DC at 10 mA. The 46CP100/120-3.75/10 model delivers approximately 0 to 100 kV AC at 37.5 mA and approximately 0 to 120 kV DC at 10 mA. On both models the DC output is negative, with the positive pole earthed. The duty cycle is 5 minutes under voltage followed by a 15 minute pause under load, at 2 kVA for the smaller model and 3.75 kVA for the larger one.

The unit runs from a 110–120 V or 220–240 V supply at 50/60 Hz. The smaller model draws 15 A or 10 A and the larger one 30 A or 20 A, depending on the mains voltage. A digital measuring unit shows the output voltage directly. The voltmeter range is 0 to 70 kV or 0 to 120 kV AC/DC, and the ammeter has several ranges up to 40 mA. Measurement error is ±(0.8% of reading + 0.2% of range). A guard circuit diverts stray currents, so the ammeter shows the leakage current through the test object alone.

Protection and controls include an input circuit breaker, external interlock terminals, illuminated high voltage on and off buttons, a start lock if the regulator is not at zero, manual output voltage adjustment, and an adjustable overload protection with an indicator and reset button. Meters and relays are protected against slow and fast transients. A digital timer sounds at the end of the dwell time, and the emergency stop button has a key lock.

The equipment is made in three parts that are moved on a hand trolley measuring 559 × 711 × 1168 mm. The housing is designed for indoor use and for open-air sites, and assembly and preparation for a test are simple. The set comes with an operating and maintenance manual, and ISO17025 calibration is available to order.

Technical specifications

Model 46CP50/70-2/10, AC output~0–50 kV, 40 mA
Model 46CP50/70-2/10, DC output~0–70 kV, 10 mA
Model 46CP100/120-3.75/10, AC output~0–100 kV, 37.5 mA
Model 46CP100/120-3.75/10, DC output~0–120 kV, 10 mA
DC polaritynegative output, positive pole earthed
Supply110–120 V or 220–240 V, 50/60 Hz
Input current15 A / 10 A (46CP50/70-2/10); 30 A / 20 A (46CP100/120-3.75/10)
Duty cycle5 min on / 15 min off at 2 kVA or 3.75 kVA
Measurement error±(0.8% of reading + 0.2% of range)
Voltmeter range0–70 kV or 0–120 kV AC/DC
Ammeter rangeseveral ranges up to 40 mA
Construction3 parts on a hand trolley
Trolley dimensions559 × 711 × 1168 mm
CalibrationISO17025 to order

Part numbers

Show all part numbers (1)

46CP50/70-2/10 and 46CP100/120-3.75/10

Request a price and lead time

46CP Combined AC/DC Hi-Potential Test System, Up to 100 kV AC and 120 kV DC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the polarity of the DC output?

The DC output is negative, with the positive pole earthed, and this is the same on both models in the 46CP series.

How long can the set run under load?

The duty cycle is 5 minutes under voltage followed by a 15 minute pause, at 2 kVA for 46CP50/70-2/10 and at 3.75 kVA for 46CP100/120-3.75/10.

What supply does the set need?

It runs from 110–120 V or 220–240 V at 50/60 Hz, and the larger model draws up to 30 A at 110–120 V.