4100-5ST-100 to 4600-5ST-100 stackable modular DC hipot test sets, 100–600 kV
Stackable high voltage DC test sets built from one to six modules, with each module adding 100 kV DC up to a maximum of 600 kV DC. Each module is rated at 5 mA and the modules are stacked on a wheeled base.
- Output voltage
- 100–600 kV DC, 100 kV steps
- Number of modules
- 1–6
- Module current
- 5 mA
- Insulation
- air
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Modular DC hipot sets are used for precise DC voltage testing of insulation in switchgear, cables, motors, generators and protective devices. They are equally suited to circuit breakers, reclosers, transformers and insulating materials. The voltage rating is chosen by the number of modules, so one platform can be built up from 100 kV DC to 600 kV DC in 100 kV steps.
A complete set consists of a wheeled base, grading rings, a control cabinet, a regulator cabinet and the required number of high-voltage modules. The modules are air insulated and cooled naturally by air (AN), and they are joined by spring-loaded contacts so no interconnecting wires are needed. Output polarity can be reversed, and ripple stays below 5 %.
The range has six models by module count, each step adding 100 kV: the 4100-5ST-100 reaches 100 kV, the 4200-5ST-100 reaches 200 kV, and so on up to the 4600-5ST-100 at 600 kV. Each module is rated at 5 mA. Output voltage is set by a motor drive, and the controls block start-up from any non-zero regulator position as well as providing an external interlock terminal.
Multi-range digital meters display the voltage and current. The guard circuit diverts stray leakage currents away from the measurement, so the current read is the current flowing through the test object. The computerised version has a 10-inch colour touch display and an Ethernet port, which lets automatic test modes be selected from a remote computer.
The sets operate from 10 to 40 °C, indoors or outdoors in dry weather, at humidity up to 95 % without condensation and at altitudes up to 1000 m. The unit is light and rugged, and it is transported to the test site fully assembled on its wheeled base. Optional items include an input cable of the required length with a plug, computerised control, a discharge device, a series high-voltage resistor, earthing and discharge rods and reusable transport containers. The GS100-2 earthing rod has two sections and a 25’ (8 m) earth lead, and an operation and maintenance manual is supplied.
Technical specifications
| Output voltage | 100–600 kV DC, 100 kV steps |
|---|---|
| Number of modules | 1–6 |
| Module current | 5 mA |
| Insulation | air |
| Cooling | AN, natural air |
| Polarity | reversible |
| Ripple | <5% |
| Voltage adjustment | motor drive |
| Display (computerised control) | 10-inch colour touch screen, Ethernet |
| Operating temperature | 10–40 °C |
| Humidity | <95% non-condensing |
| Altitude | <1000 m |
| Earthing rod | GS100-2, 2 sections, 25’ (8 m) earth lead |
Part numbers
Show all part numbers (6)
4100-5ST-100, 4200-5ST-100, 4300-5ST-100, 4400-5ST-100, 4500-5ST-100, 4600-5ST-100
Request a price and lead time
4100-5ST-100 to 4600-5ST-100 stackable modular DC hipot test sets, 100–600 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the voltage of an installed set be increased later?
Yes, the set is built up from modules of 100 kV DC each, from 100 kV to 600 kV, and the modules connect through spring-loaded contacts with no wires between them.
What current does the set supply?
Each module is rated at 5 mA, and the ripple of the output voltage is below 5 %.
Can the set be used outdoors?
Yes, in dry weather at 10–40 °C, with humidity up to 95 % non-condensing and altitudes up to 1000 m.