A capacitive divider, also called a coupling capacitor, that picks up partial discharge signals on rotating machines, whether on-line or off-line and for spot checks or continuous monitoring. It delivers a PD signal and a synchronisation signal with the reference voltage, and connects by coaxial cable through a BNC output.

Type
capacitive divider (coupling capacitor) for PD measurement
Rated voltages
17.5 kV, 20 kV, 24 kV, 50 kV, 100 kV
Rated voltage (50 kV version, phase-to-earth)
50 kVrms
Working frequency band
50 Hz to 2 kHz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The divider is used as a partial discharge (PD) sensor when testing rotating machines, motors fitted with variable speed drives and generators. The 50 kV version is intended for laboratory tests and for off-line tests on site with the equipment disconnected. It suits gas-insulated switchgear (GIS), medium voltage equipment, generators, motors, gas-insulated lines (GIL) and busbars (GIB), transformers, cables and test rigs. The sensor is compatible with the manufacturer's PD diagnostic systems and can be combined with other sensors if the customer needs it.

The high voltage is applied through the terminal on the top. The base holds a measuring impedance (Zm), from which both the PD signal and the synchronisation signal, which is the reference voltage, are taken. The same base contains a surge arrester that limits the maximum transient output voltage. The PD signal passes through a high-pass filter that blocks the test voltage, while the synchronisation signal is taken through a low-pass filter.

Its own partial discharge stays below 2 pC up to rated voltage at 50-60 Hz. Rated voltage is stated as the phase-to-earth RMS value, and the series of rated voltages is 17.5 kV, 20 kV, 24 kV, 50 kV and 100 kV. For the 50 kV version the nominal capacitance is 1 nF ±5%, and the working frequency band runs from 50 Hz to 2 kHz.

The synchronisation phase shift relative to the applied high voltage is under 1 degree at 50-60 Hz, and the synchronisation output is 1.0 V (±5%) per 1 kV applied. Attenuation at 50 Hz exceeds 140 dB over 50-60 Hz. The operating temperature range is -10 to +40 °C, or -10 to +50 °C at 50/60 Hz, and the unit weighs about 15 kg.

Technical specifications

Typecapacitive divider (coupling capacitor) for PD measurement
Rated voltages17.5 kV, 20 kV, 24 kV, 50 kV, 100 kV
Rated voltage (50 kV version, phase-to-earth)50 kVrms
Working frequency band50 Hz to 2 kHz
Capacitance Cc (nominal)1 nF ±5%
Own partial dischargebelow 2 pC up to rated voltage at 50-60 Hz
Phase shift of synchronisation signalunder 1° at 50-60 Hz
Synchronisation output per 1 kV1.0 V (±5%)
Attenuation at 50 Hz>140 dB (50-60 Hz)
Operating temperature-10 to +40 °C (-10 to +50 °C at 50/60 Hz)
Weightabout 15 kg
OutputBNC, coaxial cable

Request a price and lead time

Capacitive Divider for Partial Discharge Measurement, 17.5-100 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which rated voltages are available?

The divider is made for 17.5 kV, 20 kV, 24 kV, 50 kV and 100 kV, with the rating stated as the phase-to-earth RMS value.

What signals does the divider provide?

The measuring impedance in the base provides the PD signal and the synchronisation signal, and the 50 kV version gives 1.0 V (±5%) per 1 kV applied.

Does the coupler produce partial discharge of its own?

No, its own partial discharge stays below 2 pC up to rated voltage at 50-60 Hz.