LD liquid dielectric breakdown test sets, 60, 75 and 100 kV
LD testers measure the breakdown voltage of insulating liquids used in transformers, capacitors and bushings. Test cells are available for the main international oil test methods.
- Purpose
- breakdown voltage of insulating liquids
- LD60
- 0-60 kV at 500 VA
- LD75
- 0-75 kV at 500 VA
- LD100
- 0-100 kV at 500 VA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
LD units are used in laboratories and in the field to check the dielectric strength of transformer oil and other insulating liquids. The unit is light and sturdy, simple to set up, and works in semi-automatic mode. Calibration to ISO 17025 is available on request.
Three models are produced as standard: the LD60 with a 0 to 60 kV output, the LD75 with 0 to 75 kV and the LD100 with 0 to 100 kV AC, each rated at 500 VA. Supply is 120 V at 5 A or 230 V at 2.5 A, at 50 or 60 Hz, and the voltage and frequency are specified at ordering. The high-voltage transformer has a centre tap, so the maximum voltage to earth is 30000 V, 37500 V and 50000 V respectively.
The front panel carries a large digital voltmeter, a switch with an indicator lamp, a rate-of-rise selector, and start and reset buttons. The operator fills the test cell with the liquid, places it on the chamber contacts, selects the rise rate, closes the lid and switches to start. The unit raises the voltage automatically, a failure lamp lights when the liquid breaks down, and the voltmeter holds the breakdown reading.
The chamber has a transparent lid interlocked with the test circuit through a limit switch. A fast-acting relay cuts the voltage the moment flashover occurs, and a start interlock prevents starting from a non-zero level. Power and sample-failure lamps are fitted, along with fuses at the input and in the primary circuit of the high-voltage transformer. A socket in the chamber takes a motor-driven stirrer, which is needed for ASTM D1816 and VDE tests.
Operating conditions run from 10 to 40 °C indoors or outdoors in dry weather, with humidity below 95% non-condensing and altitude up to 1000 m. An LDCU comparison unit is available for checking the voltmeter. It holds a precision divider and an analogue meter, and it is fitted in place of the test cell.
Technical specifications
| Purpose | breakdown voltage of insulating liquids |
|---|---|
| LD60 | 0-60 kV at 500 VA |
| LD75 | 0-75 kV at 500 VA |
| LD100 | 0-100 kV at 500 VA |
| Max voltage to earth | 30000 V / 37500 V / 50000 V |
| Power supply | 120 V, 5 A or 230 V, 2.5 A |
| Mains frequency | 50 or 60 Hz |
| Operating mode | semi-automatic |
| Voltmeter | digital, with breakdown reading memory |
| Standards | VDE 0370, BS 148, IEC 60156, ASTM D877, ASTM D1816 |
| Operating temperature | 10-40 °C |
| Humidity | below 95% non-condensing |
| Altitude | below 3300 ft (1000 m) |
Part numbers
Show all part numbers (3)
LD60, LD75, LD100
Request a price and lead time
LD liquid dielectric breakdown test sets, 60, 75 and 100 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which test methods are covered?
With the appropriate test cell, the units cover ASTM, IEC, British and German methods. A stirrer socket in the chamber serves the ASTM D1816 and VDE methods.
How is the result recorded?
When the liquid breaks down, a failure lamp lights and the digital voltmeter holds the breakdown value. A fast-acting relay cuts the voltage at the moment of flashover.
How is the voltmeter checked?
With the LDCU comparison unit, which is fitted in place of the test cell. It contains a precision divider and an analogue meter for direct comparison of readings.
Similar equipment from other manufacturers