International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

C73DL112 Loadbreak Type C Cutout and Surge Arrester on a Mount, 15 kV, 110 kV BIL

A pole-top pairing of a loadbreak Type C porcelain cutout and a distribution-class surge arrester, supplied factory-assembled on one mounting. Rated 15 kV and 110 kV BIL, it suits transformer and lateral protection on overhead distribution lines.

Rated voltage
15 kV
Maximum voltage
15 kV
BIL
110 kV
Current rating
100 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

On most distribution poles a cutout and an arrester end up side by side anyway. This combination puts both on a single mounting, so the line crew lifts and bolts one assembly and the interconnection is already made. The mounting assembly is non-interchangeable: the cutout and arrester are supplied and fitted as a set.

Arrester duty options listed by the manufacturer are standard, heavy and riser pole, all in the distribution class. Choose riser pole where the line drops to an underground cable.

The cutout half is a loadbreak design, meaning it is intended for opening under load. Ratings are 15 kV rated and maximum voltage, 110 kV BIL and 100 A continuous; in the C73DL112 group the fuse holder interrupts up to 10 kA. Its porcelain insulator offers 220 mm (8.7 in) of creepage. The holder accepts universal-style fuse links from 1 A to 100 A and is replaced with T730-112T. A single-vent solid cap closes the top and the bore is lined with synthetic arc-quenching material.

Catalogue numbers follow a simple pattern. C73DL112EB has a small eyebolt and the heavy-duty NEMA B crossarm bracket; C73DL112EX swaps in the extended NEMA B bracket; C73DL112LD pairs a large eyebolt with the D-shaped pole bracket. P in the connector position denotes a parallel-groove clamp. These items are listed as non-standard material.

The assembly complies with ANSI/IEEE C37.41 and C37.42 – 2016. Temperature rise at 300 A is capped at 39 °C and radio interference voltage is referenced to 9.41 kV.

Technical specifications

Rated voltage15 kV
Maximum voltage15 kV
BIL110 kV
Current rating100 A
Fuse link range1 A to 100 A
Holder interrupting rating (C73DL112)10 kA
Creepage distance220 mm (8.7 in)
Max. temperature rise at 300 A39 °C
Radio interference voltageat 9.41 kV
Insulatorporcelain
Replacement holderT730-112T
Surge arresterdistribution class
BracketNEMA B, extended NEMA B, D-shape
StandardANSI/IEEE C37.41 & C37.42 – 2016

How it compares with similar models

ParameterC73DL112 Loadbreak Type C Cutout and Surge Arrester on a Mount, 15 kV, 110 kV BILC72DL112 Linkbreak Type C Cutout with Distribution Surge Arrester, 15 kV, 110 kV BILC730112 Loadbreak Type C Porcelain Cutout, 15 kV Class, 110 kV BIL, 100 AC720112 Linkbreak Type C Porcelain Fuse Cutout, 15 kV, 110 kV BIL, 100 A
Max. temperature rise at 300 A39 °C38 °C39 °C38 °C
Replacement holderT730-112TT720-112TT730-112TT720-112T
BracketNEMA B, extended NEMA B, D-shapeNEMA B, extended NEMA B, D-shapeNEMA B, extended NEMA B, D-shape, noneNEMA B, extended NEMA B, D-shape, none

Request a price and lead time

C73DL112 Loadbreak Type C Cutout and Surge Arrester on a Mount, 15 kV, 110 kV BIL. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the arrester be separated from the cutout and fitted elsewhere?

No. The mounting assembly is non-interchangeable, so the pair is installed as one unit; use separate devices if they must sit apart.

What replacement fuse holder does it need?

T730-112T for the C73DL112 group, rated 10 kA interrupting and taking universal links from 1 A to 100 A.

Which arrester duty ratings can be specified?

Standard, heavy and riser pole duty, all distribution class.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides