C720112 Linkbreak Type C Porcelain Fuse Cutout, 15 kV, 110 kV BIL, 100 A
A Linkbreak Type C distribution cutout with a porcelain insulator, rated 15 kV and 110 kV BIL. Used on overhead taps and transformer connections to isolate a section when its fuse link clears an overload or fault.
- Rated voltage
- 15 kV
- Maximum voltage
- 15 kV
- BIL
- 110 kV
- Current rating
- 100 A
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Spares are straightforward: the C720112 group takes the T720-112T replacement holder, rated 10 kA interrupting, and any universal-style fuse link from 1 A to 100 A. Keeping both on the van covers routine re-fusing after a fault.
In service the cutout sits on an overhead distribution pole. When its link melts on overload or short circuit, the faulted lateral or transformer is separated from the rest of the network. Ratings are 15 kV rated and maximum voltage, 110 kV BIL and 100 A continuous, with 220 mm (8.7 in) of creepage along the porcelain.
The bracket chosen changes the weight noticeably. C720112EB with the heavy-duty NEMA B crossarm bracket weighs 19.404 lb, C720112EX with the extended NEMA B bracket 21.61 lb and C720112ED with the D-shaped pole bracket 25.53 lb. These three have a small eyebolt connector; the range also lists large eyebolt (L) and parallel-groove (P) options, plus units without a bracket. Material is listed as non-standard.
The holder is closed by a single-vent solid cap and lined with synthetic arc-quenching material.
Compliance is with ANSI/IEEE C37.41 and C37.42 – 2016. Temperature rise at 300 A is limited to 38 °C, radio interference voltage is referenced to 9.41 kV and the minimum reference voltage limit is up to 14.4 kV.
Technical specifications
| Rated voltage | 15 kV |
|---|---|
| Maximum voltage | 15 kV |
| BIL | 110 kV |
| Current rating | 100 A |
| Fuse link range | 1 A to 100 A |
| Holder interrupting rating (C720112) | 10 kA |
| Creepage distance | 220 mm (8.7 in) |
| Max. temperature rise at 300 A | 38 °C |
| Radio interference voltage | at 9.41 kV |
| Insulator | porcelain |
| Replacement holder | T720-112T |
| Bracket | NEMA B, extended NEMA B, D-shape, none |
| Weight | 19.404 lb (C720112EB), 21.61 lb (C720112EX), 25.53 lb (C720112ED) |
| Standard | ANSI/IEEE C37.41 & C37.42 – 2016 |
How it compares with similar models
| Parameter | C720112 Linkbreak Type C Porcelain Fuse Cutout, 15 kV, 110 kV BIL, 100 A | C710112 / C710114 Type C Porcelain Fuse Cutout for 15 kV Overhead Lines, 110 kV BIL, 100 A | C730112 Loadbreak Type C Porcelain Cutout, 15 kV Class, 110 kV BIL, 100 A | C72DL112 Linkbreak Type C Cutout with Distribution Surge Arrester, 15 kV, 110 kV BIL |
|---|---|---|---|---|
| Max. temperature rise at 300 A | 38 °C | 38 °C | 39 °C | 38 °C |
| Replacement holder | T720-112T | — | T730-112T | T720-112T |
| Bracket | NEMA B, extended NEMA B, D-shape, none | NEMA B, extended NEMA B, D-shape, none | NEMA B, extended NEMA B, D-shape, none | NEMA B, extended NEMA B, D-shape |
Request a price and lead time
C720112 Linkbreak Type C Porcelain Fuse Cutout, 15 kV, 110 kV BIL, 100 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What do the bracketed versions weigh?
C720112EB with the NEMA B bracket is 19.404 lb, C720112EX with the extended bracket 21.61 lb and C720112ED with the D-shaped bracket 25.53 lb.
Which fuse links can be used?
Universal-style links from 1 A to 100 A, in the T720-112T holder rated 10 kA.
What voltage class is the cutout for?
15 kV rated and maximum voltage, 110 kV BIL, 100 A continuous.