RESIBLOC® dry cast-resin transformers up to 36 kV

RESIBLOC® dry cast-resin transformers for HV up to 36 kV and LV up to 24 kV. The windings are cast in glass-fibre-reinforced epoxy resin without a mould, which gives increased mechanical strength.

Voltage
HV up to 36 kV, LV up to 24 kV
Classes
E2–E4, C2–C4, F1
Frequency
50, 60 and 16⅔ Hz
Cooling
AN, ANAN, ANAF, AFWF

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The strength margin is designed for cyclic loads, short circuits and harsh climates. The transformers comply with classes E2–E4, C2–C4 and F1, the partial discharge level is below 10 pC. Frequency is 50, 60 or 16⅔ Hz, cooling AN, ANAN, ANAF or AFWF. Thermal class F, degree of protection from IP00 to IP54.

Technical specifications

VoltageHV up to 36 kV, LV up to 24 kV
ClassesE2–E4, C2–C4, F1
Frequency50, 60 and 16⅔ Hz
CoolingAN, ANAN, ANAF, AFWF
Thermal classF
Partial discharge< 10 pC
Degree of protectionIP00 – IP54

Replacement for

ТСЛ-630/10, ТСЛ-1000/10, ТСЗЛ-1600/10, ТСЗГЛ-2500/10; ТСЗ-…/10; dry 20–35 kV: ТСЛ/ТСЗЛ (general type)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

RESIBLOC® dry cast-resin transformers up to 36 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 31 80 00
8504 32 00 90
8504 33 00 90
8504 34 00 00
HS, 6 digits8504 34
CN (EU)8504 31 80
8504 32 00
8504 33 00
8504 34 00
HTSUS (USA)8504 31 40 35
8504 31 40 65
8504 31 60 00
8504 32 00 00
8504 33 00 20
8504 33 00 40
8504 34 00 00
China customs tariff8504 31 90 00
8504 32 90 00
8504 33 90 00
8504 34 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How does RESIBLOC insulation differ from ordinary cast resin?

The windings are cast in glass-fibre-reinforced epoxy resin without a mould, which increases mechanical strength.

What climatic and environmental classes does the transformer have?

E2–E4, C2–C4 and F1, the partial discharge level is below 10 pC.

What voltage and frequency is RESIBLOC designed for?

HV up to 36 kV, LV up to 24 kV, frequency 50, 60 or 16⅔ Hz.