Cast-resin dry-type transformer 160–2500 kVA

A cast-resin dry-type transformer rated 160–2500 kVA, with a primary voltage of 5–35 kV and a secondary of 410 V. It is installed inside buildings with increased fire safety requirements.

Power
160–2500 kVA
Primary voltage
5–35 kV, ±2.5 % / ±5 %
Secondary voltage
410 V
Cooling
AN

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Typical sites include hospitals, shopping centers, data centers and office buildings. The windings are cast in epoxy resin, and cooling is natural air AN. The transformer is made to classes E2, C2 and F1. The primary voltage is regulated by ±2.5 % or ±5 %. There is no oil in the design, so the transformer can be installed next to rooms where people are present.

Technical specifications

Power160–2500 kVA
Primary voltage5–35 kV, ±2.5 % / ±5 %
Secondary voltage410 V
CoolingAN
Insulationwindings in epoxy resin
ClassesE2, C2, F1

Replacement for

ТСЛ-630/10, ТСЛ-1000/10, ТСЗЛ-1600/10, ТСЗГЛ-2500/10; ТСЗ-…/10; dry-type 20–35 kV: ТСЛ/ТСЗЛ (general type)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Cast-resin dry-type transformer 160–2500 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 33 00 90
8504 34 00 00
HS, 6 digits8504 34
CN (EU)8504 33 00
8504 34 00
HTSUS (USA)8504 33 00 40
8504 34 00 00
China customs tariff8504 33 90 00
8504 34 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What classes does the cast-resin transformer have?

The transformer is made to classes E2, C2 and F1, and the windings are cast in epoxy resin.

What facilities is the dry-type transformer suitable for?

For indoor installation in buildings with increased fire safety requirements, for example hospitals, shopping centers, data centers and office buildings.

What are the power and voltage ranges?

Power 160–2500 kVA, primary voltage 5–35 kV with regulation of ±2.5 % or ±5 %, secondary 410 V.