International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Cast resin dry-type transformer 6–30 kV, 50 kVA–20 MVA

Cast resin dry-type transformers with voltage 6–30 kV and power 50 kVA – 20 MVA. Used in premises with increased fire safety requirements, in humid and polluted environments, and at wind and PV plants.

Rated voltage
6–30 kV
Power
50 kVA – 20 MVA
Insulation
HV winding cast in epoxy resin under vacuum
Classes
E3, C3, F1 to IEC 60076-11/-16 (CESI/KEMA certificate)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The HV winding is cast in epoxy resin under vacuum, and there is no liquid in the transformer. Classes E3, C3 and F1 are confirmed by tests to IEC 60076-11/-16, and a CESI/KEMA certificate is available. This combination of classes matches the conditions the series is intended for, namely humid and polluted premises and sites with fire safety requirements. The plant's production capacity is 5 000 units per year.

Technical specifications

Rated voltage6–30 kV
Power50 kVA – 20 MVA
InsulationHV winding cast in epoxy resin under vacuum
ClassesE3, C3, F1 to IEC 60076-11/-16 (CESI/KEMA certificate)
Production capacity5 000 pcs/year

Replacement for

ТСЛ-630/10, ТСЛ-1000/10, ТСЗЛ-1600/10, ТСЗГЛ-2500/10; ТСЗ-…/10; dry-type 20–35 kV — ТСЛ/ТСЗЛ (general type); above 4000 kVA and above 35 kV there is no direct series analog

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Cast resin dry-type transformer 6–30 kV, 50 kVA–20 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 33 00 90
8504 34 00 00
HS, 6 digits8504 34
CN (EU)8504 33 00
8504 34 00
HTSUS (USA)8504 33 00 20
8504 33 00 40
8504 34 00 00
China customs tariff8504 33 90 00
8504 34 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which resistance classes does the transformer have?

Classes E3, C3 and F1 to IEC 60076-11/-16, confirmed by a CESI/KEMA certificate.

What is the voltage and power range?

From 6 to 30 kV and from 50 kVA to 20 MVA.

How is the winding insulation made?

The HV winding is cast in epoxy resin under vacuum, the transformer is dry, with no liquid dielectric.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides