ТМГ-160/10 (TMG-160/10) — three-phase hermetically sealed oil-immersed power transformer
Stepping down distribution-network voltage to supply consumers at transformer substations of urban and rural networks and industrial plants.
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Stepping down distribution-network voltage to supply consumers at transformer substations of urban and rural networks and industrial plants.
Technical specifications
| Type | Three-phase hermetically sealed oil-immersed power transformer |
|---|---|
| Designation | ТМГ-160/10 |
| Parameter | rated power (per designation) 160 kVA |
| HV winding voltage class 10 kV |
Request a price and lead time
ТМГ-160/10. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
European analogues of ТМГ-160/10

Oil-immersed distribution transformersThree-phase liquid-filled distribution transformer 6–72.5 kV, 25 kVA – 5 MVA

Oil-immersed distribution transformersOil-immersed transformer with built-in switch-fuse 100–250 kVA, 5–35 kV

Special transformersAuxiliary services transformer for HV/MV substations, 100–250 kVA, 5–36 kV

Reactors and arc suppression coilsEarthing and auxiliary transformers for substations and power plants

Oil-immersed distribution transformersOil-filled distribution transformer 25 kVA to 30 MVA, Ecodesign Tier I/II

Special transformersSmall oil-immersed distribution transformers 30–1000 kVA, primary voltage up to 36 kV

Oil-immersed distribution transformersTOd — oil-immersed distribution transformers 40–2500 kVA, up to 37 kV

Reactors and arc suppression coilsEarthing and auxiliary transformers, example version ZT 500 kVA 34/0.4 kV

Oil-immersed distribution transformersOil-immersed distribution transformers 50–1600 kVA, HV up to 24 kV, Ecodesign Tier 2
Analogue selection is for reference only, by purpose and connection dimensions. Before replacement, check the specifications and wiring diagram against the product passport.
Designations of the ТМГ series
| ТМГ-16/10 | rated power (per designation) 16 kVA; HV winding voltage class 10 kV |
|---|---|
| ТМГ-25/10 | rated power (per designation) 25 kVA; HV winding voltage class 10 kV |
| ТМГ-40/10 | rated power (per designation) 40 kVA; HV winding voltage class 10 kV |
| ТМГ-63/10 | rated power (per designation) 63 kVA; HV winding voltage class 10 kV |
| ТМГ-100/10 | rated power (per designation) 100 kVA; HV winding voltage class 10 kV |
| ТМГ-160/10 | rated power (per designation) 160 kVA; HV winding voltage class 10 kV |
| ТМГ-250/10 | rated power (per designation) 250 kVA; HV winding voltage class 10 kV |
| ТМГ-400/10 | rated power (per designation) 400 kVA; HV winding voltage class 10 kV |
| ТМГ-630/10 | rated power (per designation) 630 kVA; HV winding voltage class 10 kV |
| ТМГ-1000/10 | rated power (per designation) 1000 kVA; HV winding voltage class 10 kV |
| ТМГ-1600/10 | rated power (per designation) 1600 kVA; HV winding voltage class 10 kV |
| ТМГ-2500/10 | rated power (per designation) 2500 kVA; HV winding voltage class 10 kV |